     AUTOMATIC BYPASS OPTION

    

K

If checked, the "AUTOMATIC BYPASS" option has been selected by your installing company.
With this feature enabled, all interior zones will automatically bypass if you "ARM" your security
system and do not leave through a designated entry/exit door.  The "AUTOMATIC BYPASS"
will occur at the end of the exit delay time. At this time, all bypassed "ZONE" lights will become
illuminated. With the interior zones bypassed, occupants are allowed the freedom of movement
inside of the Home/Business while the security system is "ARMED".  If enabled by the installer,
interior zones that have bypassed automatically can be unbypassed by pressing [X] - [

U

]

(X=the first digit of the Master Code).  Check with the installing company to see if your system
has this option.

     INSTANT / DELAY OPTION

 

If checked, the "INSTANT" option has been selected by your installing company. With this
feature enabled, if you do not wish to have a delay on your entry/exit doors, this can be
accomplished by pressing the [

U

] key on your keypad while the system is "ARMED". At this

time, the "INSTANT" light will illuminate and there will be no entry delay when the entry/exit
doors are opened. Any time the "INSTANT" light is on and the exit delay has expired, the
opening of an entry/exit door will produce an immediate alarm, making this feature ideal when
a high level of security is desired, and no authorized entries are anticipated. By pressing the
[

U

] key again, the "INSTANT" light will turn off, and an entry delay will be present on

designated entry/exit doors.

NOTE: Your installing company may have programmed the "INSTANT" option to occur in
conjunction with the "AUTOMATIC BYPASS" feature. In this case, the "INSTANT" light and the
bypassed "ZONE" lights will become illuminated at the end of the exit delay. If this occurs, you
still have the ability to turn the "INSTANT" feature off, and/or on by pressing the [

U

] key.

     GROUP BYPASS OPTION

    

K

If checked, the "GROUP BYPASS" option has been selected by your installing company. If you
wish to bypass all zones designated as "GROUP BYPASS" zones, do so by entering [

U

]-[9]-[

U

]

while the system is disarmed. Once these zones have been bypassed, they will remain
bypassed until the system is armed and disarmed.

     FORCE ARMING OPTION

    

K

If checked, the "FORCE ARMING" option has been selected by your installing company. Force
arming allows the system to be armed without a green "READY" light illuminated. Any zones
that restore prior to the end of the exit delay will become active in the system, while those
zones that do not restore prior to the end of the exit delay will become bypassed zones.
Caution: If this feature is selected, an intrusion through one of the bypassed zones will not be
detected.

     AUTOMATIC ARMING OPTION

    

K

If checked, the "Automatic Arming" option has been selected by your installing company. This
feature is used to make your system automatically arm itself at a designated time of day, if it
is not already armed. The keypad will sound a continuous beeping  tone for a 50 second time
frame before automatically arming. If a valid code is entered during this time frame, the system
will not automatically arm. When automatic arming occurs, all zones that are not secure, will
become bypassed.

(

K

)   These features cannot be enabled on UL listed systems.

www.ealarm.com.my

Summary of Contents for 8600

Page 1: ...LATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS AND USE THEM WHEN PREPARING A SAFETY SECURITY PLAN FOR YOUR HOME BUSINESS 1 Your security system is an electron...

Page 2: ...ssed NOTE If the exit door is open when the exit delay expires the siren will sound and the entry delay will begin If a valid code is not entered prior to the expiration of the entry delay an alarm report will be transmitted to the monitoring station if the system is monitored Entering a valid code during the entry delay will disarm the system silence the siren and keep an alarm report from being ...

Page 3: ...installing company may have programmed the INSTANT option to occur in conjunction with the AUTOMATIC BYPASS feature In this case the INSTANT light and the bypassed ZONE lights will become illuminated at the end of the exit delay If this occurs you still have the ability to turn the INSTANT feature off and or on by pressing the U key GROUP BYPASS OPTION K If checked the GROUP BYPASS option has been...

Page 4: ...ond to the Panic Hold Up activation KEYPAD ACTIVATED FIRE ALARM If checked this feature has been selected by your installing company If so you can activate the Fire alarm by pressing the one 1 and three 3 keys at the same time for one second If your system is connected to a monitoring center an emergency report could be sent to that center These keys should only be pressed in an emergency situatio...

Page 5: ...de 1 and up to 13 auxiliary codes All codes must have 4 digits These Auxiliary codes are individually numbered from 2 to 14 NOTE If your system is programmed for a DURESS code mentioned above user code 7 will not be available If Auxiliary codes are desired they must be programmed individually Codes 2 thru 7 can be changed by the procedures described below while codes 8 thru 14 can only be changed ...

Page 6: ... the system standby battery is low ZONES YELLOW Flashing means unsecured Steady means bypassed Off means secure KEYPAD CONTROL TONES BEEPS A sounder is built into the keypad and may sound for any of the following reasons Beeps for all keypresses Sounds a continuous tone during the Entry delay time Pulses when a day zone is violated while the system is disarmed Pulses when a FIRE zone has a trouble...

Page 7: ...one light should blink Walk into all areas protected by motion detection devices while someone observes the Keypad Control The appropriate yellow zone light should blink for each sensor tested If your system has a FIRE Zone the Smoke or Heat detectors should be tested at least monthly If your Security System is monitored by a Central Monitoring Station always call before to let them know that you ...

Reviews: