background image

1

1

CAUTION

Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to 

avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation 

must be provided.

IMPORTANT

Read these instructions carefully so as to familiarise yourself with the appliance before fi ting the appliance to a gas cylinder.

Retain these instructions for future reference.

GB

1. General

•  The CADAC Trio is a light weight, compact LPG source for CADAC and other camping products, it replaces a gas cylinder and regulator. 

You fi t the gas cartridges into the Trio Power Pak and then to a camping stove or BBQ.

•  This regulator complies with EN16129:2013 and SANS 1539:2017.

•  Appliance category: I3B(28-30mbar) All EU, NO, IS, CH, TR, DE, AT and LU

•  Appliance category: I3B(50mbar) DE, AT and LU

•  Only to be used with EN417 type disposable cartridges (CADAC CAN220G).

•  The Trio Power Pak is to be used only in the horizontal position.

•  Gas appliances require ventilation for effi cient performance and to ensure the safety of users and other persons in close proximity.

•  The Power Pak is fi tted with a regulator with a maximum supply rate of 1.0kg/hour.

•  The user may adjust the supply rate of the Power Pak unit by turning the control valve on the Power Pak from fully closed to fully open.

2. Safety information

•  The Trio Power Pak is guaranteed for a period of 2 years against factory faults. 

Natural wear and tear and valve components are excluded. Warranty excludes 

damage caused by improper handling, misuse or repair by an unauthorized LP gas 

dealer. Liability is limited to replacement of products. Never use in an unventilated 

room with all windows and doors closed.

•  Never place the Trio Power Pak on a stove, and always keep it at least 1 meter away 

from any source of heat (Fig. 1), and ensure it is not placed in an environment 

where the temperature will exceed 40°C.

•  Always store, transport or use the Trio Power Pak in a horizontal position as seen in 

images in this guide.

•  When not in use, keep the valve closed.

•  Do not use an appliance which is leaking, damaged or which does not operate 

properly (malfunctioning). 

•  If you suspect a gas leak, soapy water must be applied to the joints (the appliance 

must not be fully immersed in soapy water as this may result in an unsafe operation 

of the appliance). Any leakage will be seen as bubbles coming from the leakage 

point. If you cannot remedy any leakage, unscrew the gas cartridge from the 

appliance and return the appliance to your stockist.

•  The appliance should only be used in a well-ventilated location (minimum 

ventilation requirement 5m3/h) in order to satisfy offi cial ventilation standards for 

the supply of suffi cient combustion air and to avoid the dangerous building up of 

unburned gases.

•  Gas cartridges must be fi tted or changed in a well-ventilated location, preferably 

outside and away from any sources of ignition, such as naked fl ames, pilots, 

electric fi res and away from other people.

•  Never leave the appliance unattended when in use.

•  Do not modify the appliance. Do not use it for anything for which it has not been designed.

Country name abbreviations

AT=Austria

DK=Denmark

GB=UnitedKingdom

NO=Norway

BE=Belgium

ES=Spain

IE=Ireland

PL=Poland

CH=Switzerland

FI=Finland

IT=Italy

PT=Portugal

DE=Germany

FR=France

NL=Netherlands

SE=Sweden

SI=Slovenia

1m

1m

1m

1m

Fig. 1

Low pressured 

gas

High pressured gas

Fig. 2

Valve outlet

3. Assembly & Operation

•  First ensure the control knob on the Trio Power Pak is in the “off” position.

•  Ensure that the hose is connected securely to the valve outlet of the Power Pak (Fig. 2).

•  Connect the other end of the hose securely to the appliance you wish to operate, using the hand wheel to tighten (Fig. 3).

 

1: Hand wheel (17mm Hex) and hose component

 

2: Move the handle wheel to the end of the hose sliding it over the brass nut.

 

3: Connect brass nut to the inlet of the BBQ, turn the hand wheel to tighten.

503-0766 LEV2 (370) Trio Power Pak K3 - User Manual (All).indd   1

2019/12/19   15:19:45

Summary of Contents for 370

Page 1: ...IO POWER PAK 503 0766 LEV2 USER INSTRUCTIONS NOTE PRODUCT MAY VARY FROM ILLUSTRATIONS GB DE DK ES FR IT NL NO PL SE LIVE THE BRAAI LIFE 503 0766 LEV2 370 Trio Power Pak K3 User Manual All indd 1 2019...

Page 2: ...503 0766 LEV2 370 Trio Power Pak K3 User Manual All indd 2 2019 12 19 15 19 41...

Page 3: ...rature will exceed 40 C Always store transport or use the Trio Power Pak in a horizontal position as seen in images in this guide When not in use keep the valve closed Do not use an appliance which is...

Page 4: ...from the appliance and pack the unit away for storage Cartridges should always be stored in a cool dry well ventilated area 5 Checking for leaks Gas cartridge To check the gas cartridge for leaks appl...

Page 5: ...r Umgebung befindet in der die Temperatur 40 C bersteigt Vor dem Gebrauch etwas Gas nicht zu viel austreten lassen um sicher zu gehen dass alle Ventil ffnungen frei und nicht durch Staub blockiert sin...

Page 6: ...eiben wollen ein und z nden es Stellen Sie die Bedienkn pfe auf die gew nschte Hitze ein Stellen Sie den Drehknopf um den gew nschten Gasstrom auf dem Ger t zu erreichen 4 Um das Ger t zu zerlegen Sch...

Page 7: ...en klein beetje gas niet te veel ontsnappen om ervoor te zorgen dat alle openingen bij het ventiel ongeblokkeerd en stofvrij zijn Doe dit buiten en uit de buurt van ontstekingsbronnen of open vuur Bew...

Page 8: ...gastoevoer wordt bereikt De warmte van het toestel regelt u vervolgens met de regelknop van het toestel 4 Om het apparaat te demonteren Sluit de regelknop van de Power Pak Verwijder de cartridges door...

Page 9: ...arder au moins 1 m de toute source de chaleur Fig 1 S assurer par ailleurs de ne pas le placer dans un environnement o la temp rature exc de 40 C Avant toute utilisation laisser chapper un peu de gaz...

Page 10: ...r les boutons de commande pour atteindre le niveau de chaleur souhait R glez le bouton de commande pour atteindre le d bit de gaz au niveau d sir de l appareil Le contr le de la chaleur peut se faire...

Page 11: ...e Pass p at dette skjer utend rs og borte fra tennkilder og pen ild Power Pak m alltid lagres transporteres og brukes i st ende stilling N r den ikke er i bruk m ventilen stenges selv om den er tom Br...

Page 12: ...g se om noen bobler er synlige Enhver lekkasje vil bli sett p som bobler som kommer fra lekkasjepunktet Hvis du ikke kan rette en eventuell lekkasje tilbake kassetten til din forhandler NO Fig 5 Messi...

Page 13: ...s i uventilerede rum hvor alle vinduer og d re er lukket S t aldrig Power Pak p en ovn og s rg altid for mindst 1 meter afstand fra alle varmekilder og forvis dig om Fig 1 at Power Pak ikke bliver ops...

Page 14: ...ppen for at n gasstr mmen nskede niveau p apparatet Varmestyring at ske ved hj lp af apparatet kontrolknap 4 At skille apparatet Luk betjeningsknappen Tag patronen ved at skrue det Tag slangen fra app...

Page 15: ...e gas LP no autorizado La responsabilidad se limita a la sustituci n de los productos No utilizar nunca en una habitaci n sin ventilaci n con todas las ventanas y las puertas cerradas Nunca colocar el...

Page 16: ...a alcanzar el nivel de calor deseado Ajuste el mando de control para alcanzar el nivel deseado de flujo de gas al aparato Regulaci n de la temperatura debe hacerse con el mando de control del aparato...

Page 17: ...i riscontrate difettose Non operare in ambienti con finestre e porte chiuse Non sistemare l apparecchio Power Pak su stufe e tenerlo sempre alla distanza di almeno 1 metro dalle sorgenti di calore Fig...

Page 18: ...ello desiderato all apparecchio Controllo di calore per essere fatto utilizzando la manopola di controllo apparecchio 4 Per smontare l unit Chiudere la manopola di controllo Rimuovere la cartuccia svi...

Page 19: ...o u ywa w pomieszczeniach bez wentylacji z zamkni tymi wszystkimi oknami i drzwiami Nigdy nie wolno umieszcza Power Pak na kuchence zawsze trzeba ustawia to urz dzenie co najmniej 1 metr od ka dego r...

Page 20: ...owa pokr t a sterowania do danego poziomu ciep a 4 Do demonta u Zamkn pokr t o sterowania Wyjmij kaset odkr caj c go Od czy przew d od urz dzenia i zapakowa urz dzenie z dala do przechowywania Kasety...

Page 21: ...n obeh rig gasol leverant r V r ansvarsskyldighet begr nsas till byte av produkter F r aldrig anv ndas i utrymmen utan ventilation och med alla f nster och d rrar st ngda Placera aldrig en PowerPak p...

Page 22: ...n V rme kontroll som ska g ras med apparaten reglaget 4 F r att ta is r enheten St ng vredet Ta ut kassetten genom att skruva loss den Koppla loss slangen fr n maskinen och packa undan enheten f r f r...

Page 23: ...21 21 503 0766 LEV2 370 Trio Power Pak K3 User Manual All indd 21 2019 12 19 15 21 30...

Page 24: ...hran Iran Tel 98 21 276 00 781 Mail info cadac ir CADAC KOREA Suite 502 Pika Bldg Hogye Dong Anyang Si Gyeonggi Do South Korea Tel 82 31 427 5466 cadackorea gmail com CADAC MALAYSIA Katrin BJ SDN BHD...