5.1.1.
Identify Drive—ECH
The Identify Drive command enables the host to receive parameter information from the
drive. This command has the same protocol as the Read Sector(s) command. The parameter
words in the buffer have the arrangement and meanings defined in Table 5-7. All reserved
bits or words are zero. Table 5-7 is the definition for each field in the Identify Drive
Information.
Table 5-7. Identify Drive Information
Word
Address
Default Value
Total Bytes
Data Field Type Information
0
0040H
2
General configuration bit-significant information.
1
3FFFH
2
Default number of cylinders; capacity dependent.
2
C837H
2
Reserved
3
0010H
2
Default number of heads; capacity dependent.
4-5
0H
4
Retired
6
003FH
2
Default number of sectors per track; capacity dependent.
7-8
0h
4
Reserved
9
0H
2
Retired
10-19
aaaa
20
Serial number in ASCII (Right Justified).
20-21
0H
4
Retired
22
0H
2
Obsolete
23-26
aaaa
8
Firmware revision in ASCII . Big Endian Byte Order in Word.
27-46
aaaa
40
Model number in ASCII (Left Justified) Big Endian Byte Order in Word.
47
8001H
2
Maximum number of sectors on Read/Write Multiple command: 2
48
4000H
2
Trusted Computing Feature Set
49
2F00H
2
Capabilities: DMA, LBA, IORDY supported
50
4000H
2
Capabilities: device specific standby timer minimum
51
0H
2
Obsolete
52
0H
2
Obsolete
53
0007H
2
Words 88 and 70:64 valid
54
3FFFH
2
Obsolete
55
0010H
2
Obsolete
56
003FH
2
Obsolete
57-58
0H
4
Obsolete
59
0101H
2
Number of sectors transferred per interrupt
60-62
XXXX
6
Total number of sectors addressable
63
0007H
2
Multiword DMA modes 0-2 are supported; upper byte reflects currently
selected MWDMA mode.
64
0003H
2
Advanced PIO modes supported (modes 3 and 4)
65
0078H
2
Minimum MWDMA cycle time per word is 120ns.
66
0078H
2
Recommended MWDMA cycle time is 120ns.
67
0078H
2
Minimum PIO cycle time without IORDY flow control is 120ns.
68
0078H
2
Minimum PIO cycle time with IORDY flow control is 120ns.
Cactus Technologies Limited
Commercial Grade -250SH Series SSD Product Manual
v2.1
18