background image

- 3 -

Safety .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Introduction   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Principles of Operation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Sequence of Operation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Installation Options and Effect of Water Characteristics .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Operating Modes  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Display Panel  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
Humidifier Control & Operating Instructions .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9
Check the Humidifier Operation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
Additional Information .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

TABLE OF CONTENTS

- 2 -

 WARNING

HOT SURFACES AND HOT WATER

This steam humidification system has extremely hot surfaces. 
Water in steam canister, steam pipes, and dispersion tube can be 
as hot as 212°F (100°C). Discharged steam is not visible. Contact 
with hot surfaces, discharged hot water, or air into which steam 
has been discharged can cause severe personal injury. To avoid 
severe burns, follow procedures in this manual when performing 
service or maintenance procedures on any part of the system.

DISCONNECT ELECTRICAL POWER

Disconnect electrical power before installing supply wiring or 
performing service or maintenance procedures on any part 
of the humidification system. Failure to disconnect electrical 
power could result in fire, electrical shock, and other hazardous 
conditions. These hazardous conditions could cause property 
damage, personal injury, or death.
Contact with energized circuits can cause property damage, 
severe personal injury, or death as a result of electrical shock 
or fire. Do not remove access panels until electrical power is 
disconnected.
Follow the shutdown procedure in this manual before performing 
service or maintenance procedures on any part of the system.

ELECTRICAL SHOCK HAZARD

If the humidifier starts up responding to a call for humidity during 
maintenance, severe bodily injury or death from electrical 
shock could occur. Follow the procedures in this manual before 
performing service or maintenance procedures on this humidifier.

EXCESSIVE SUPPLY WATER PRESSURE

Supply water pressure greater than 120 psi may cause the 
humidifier to overflow.

SHARP EDGES

Sharp edges may cause serious injury from cuts. Use care when 
cutting plenum openings and handling ductwork.

 CAUTION

ATTENTION

Read this manual before installing. This product must be 
installed by qualified HVAC and electrical contractors and in 
compliance with local, state, federal, and governing codes. 
Improper installation can cause property damage, severe 
personal injury, or death as a result of electric shock, burns,  
or fire.

Read all cautions and instructions.

Read this manual before performing service or maintenance 
procedures on any part of the system. Failure to follow all 
cautions and instructions could produce the hazardous 
situations described, resulting in property damage, personal 
injury, or death.
Failure to follow the instructions in this manual can cause 
moisture to accumulate, which can cause damage to structure 
and furnishings.

EXCESS HUMIDITY

Do not set humidity higher than recommended. Condensation 
may cause damage.

SAFETY

Summary of Contents for HUM STM3034 Series

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Model HUMCRSTM3134 HUMXXSTM3034 HUMXXSTM3134 Residential Steam Humidifier Owner s Manual Includes Safety Operating Instructions Residential Steam Humidifier...

Page 2: ...until electrical power is disconnected Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system ELECTRICAL SHOCK HAZARD If the humidif...

Page 3: ...and Canister 90 1522 Steam Outlet Drain Supply Water Drain Cup Drain Valve Canister Electrodes High Water Level Sensor Flow Control Orifice Inlet Fill Valve Overflow Fill Fill Cup Thank you for your...

Page 4: ...s time the Steam light illuminates green If the humidifier cannot produce steam at the rated level after trying for 168 hours the Steam light illuminates yellow The humidifier continues to operate in...

Page 5: ...ent level below 75 of the maximum operating current Humidifier continues to operate but at reduced capacity Solid Red Operational problem with humidifier Humidifier shuts down Occurs when unit detects...

Page 6: ...HOCK HAZARD Disconnect main electrical power to the humidifier at the circuit breaker and drain the water from unit before servicing Hot surface inside NOTICE Service should be performed by an HVAC te...

Page 7: ...w O ring O ring is provided with Model 8045HUM canister into slot in drain assembly Dampen O ring with water before inserting canister Do not use oil grease or any lubricant besides water 12 Make sure...

Page 8: ...er relay One wire either one but not both must go through current sensing toroid see FIGURE 3A Electrode wires are interchangeable and can be placed on either of the two terminals FILL VALVE SERVICE 1...

Page 9: ...Catalog No OM HUMCRSTM 02 10016625 B2210113B 02 23 2023 CAC BDP 7310 West Morris St Indianapolis IN 46231...