background image

Industrieller Luftentfeuchter mit Standardkapazität 

― 

Light Capacity Industrial 

Dehumidifier

361000001-13

ST-12L-DH-ME / ST-16L-DH-ME / ST-20L-DH-ME

Summary of Contents for ST-12L-DH-ME

Page 1: ...Industrieller Luftentfeuchter mit Standardkapazität Light Capacity Industrial Dehumidifier 361000001 13 ST 12L DH ME ST 16L DH ME ST 20L DH ME ...

Page 2: ...D ES MIT STROM VERSORGT WIRD NIEMALS UNBEAUFSICHTIGT Bitte Bedienungsanleitung lesen Wenn dieses Symbol auf einem Produkt abgebildet ist lesen Sie bitte die Bedienungsanleitung Read The Instruction manual When this symbol is marked on a product it means that the instructon manual must be read GERMAN 1 6 11 12 ENGLISH 1 3 7 10 11 12 1 ...

Page 3: ...OCHLEISTUNGSLUFTENTFEUCHTER WÄHREND ES MIT STROM VERSORGT WIRD NIEMALS UNBEAUFSICHTIGT 1 2 3 4 5 1 Handle 2 Control Knob 3 Top Guard 4 Water Tank 5 Filter Cover 6 Wheel 1 Handgriff 2 Feuchtigkeitsregler 3 Obere Abdeckung 4 Wasserbehälter 5 Filterdeckel 6 Rad 6 2 ST 12L DH ME ST 16L DH ME ST 20L DH ME ...

Page 4: ...0 480 Luftstrom CMH 126 126 135 Betriebsbereich 5 32 C 5 32 C 5 32 C Kältemittel R134A CFC Free R134A CFC Free R134A CFC Free Tankinhalt L 2 3 2 3 2 3 Technische Daten Änderungen vorbehalten ST 12L DH ME ST 16L DH ME ST 20L DH ME Voltage Hz 220 240 50Hz 220 240 50Hz 220 240 50Hz Watts 260 410 480 Air Flow CMH 126 126 135 Operation Range 5 32 C 5 32 C 5 32 C Refrigerant R134A CFC Free R134A CFC Fre...

Page 5: ...ter Verwenden Sie den Luftentfeuchter NIEMALS mit einem externen Schaltgerät z B einer Zeitschaltuhr Stellen Sie die Temperatur des Luftentfeuchters NIEMALS höher als die Umgebungstemperatur ein Leeren Sie den Auffangbehälter bevor Sie den Luftentfeuchter bewegen oder aufbewahren Wird der Luftentfeuchter enteist warten Sie bis der Zyklus abgeschlossen ist bevor Sie ihn von der Stromversorgung tren...

Page 6: ...regler auf den gewünschten Feuchtigkeitswert Ausschalten des Entfeuchters 1 Drehen Sie den Feuchtigkeitsregler auf OFF AUS 2 Wenn der Entfeuchter für einige Stunden nicht wieder eingesetzt wird trennen Sie das Netzkabel von der Steckdose Feuchtigkeitseinstellungen 1 Feuchtigkeitseinstellungen am Regler HINWEIS Wenn sich der Entfeuchter im Dauerbetrieb befindet schaltet er sich nicht aus Einstellun...

Page 7: ... ist NICHT im Lieferumfang enthalten 1 Um den PVC Schlauch zu installieren müssen Sie den Wasserbehälter entnehmen und den Schlauch in die Ablauföffnung stecken 2 Setzen Sie den Wasserbehälter erneut ein falls der Schlauch verrutscht ist 3 Stellen Sie sicher dass sich das Ende des Ablaufschlauchs an einem tiefergelegenen Punkt als der Luftentfeuchter befindet um einen ordnungsgemäßen Ablauf des Ko...

Page 8: ...re that you know how to switch the dehumidifier off in an emergency ALWAYS use only the electrical power voltage and frequency specified on the model plate of the dehumidifier ALWAYS use an extension cord properly rated for this appliance ALWAYS install the dehumidifier so that it is not directly exposed to water spray rain or dripping water ALWAYS ensure that all cords are protected against short...

Page 9: ...ntrol Knob to the desired humidity setting Turning Off The Dehumidifier 1 Turn the Humidity Control Knob to the OFF position 2 If the dehumidifier will not be used again within a few hours disconnect the power cord from the electrical outlet Humidity Settings 1 Humidity settings on the Control Knob NOTE The Dehumidifier will not turn off when operating in Continuous Mode Control Knob Setting Appro...

Page 10: ...gured to drain continuously with a piece of PVC tubing NOTE PVC tubing NOT included with this unit 1 To install PVC tubing remove water tank and plug tubing into drain hole 2 Replace the water tank in case tubing becomes dislodged 3 Be sure to place drain tube at a lower point than dehumidifier to ensure proper draining and water flow Filter Cleaning 1 Remove the water tank before removing filter ...

Page 11: ...llowing code Blue Neutral Brown Live Green Yellow Earth As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your plug proceed as follows The blue wire must be connected to the terminal marked with an N or colored black The brown wire must be connected to the terminal marked with an L or colored red The green yello...

Page 12: ...oad 302 Yardley PA 19067 LASSEN SIE DAS HOCHLEISTUNGSLUFTENTFEUCHTER WÄHREND ES MIT STROM VERSORGT WIRD NIEMALS UNBEAUFSICHTIGT 1 2 3 7 8 9 10 11 4 12 13 5 6 Explosionsdarstellung Exploded View 17 1 2 3 4 5 6 7 8 9 10 11 ST 12L DH ME ST 16L DH ME ST 20L DH ME ...

Page 13: ...01 36 008 0002 36 008 0003 2 36 020 0001 36 020 0002 36 020 0003 3 36 025 0001 36 023 0001 36 023 0005 4 36 024 0001 36 023 0002 36 023 0006 5 36 012 0001 36 025 0012 36 025 0012 6 36 013 0001 36 024 0012 36 024 0012 7 36 003 0001 36 012 0002 36 001 0003 8 36 002 0001 36 013 0002 36 013 0003 9 36 022 0001 36 003 0002 36 003 0003 10 36 030 0001 36 002 0002 36 002 0003 11 36 026 0001 36 022 0002 36 ...

Page 14: ...nc Yardley PA USA www pinnacleint com 2015 Stanley Black Decker Inc STANLEY The STANLEY Logo The Notched Rectangle and the Yellow and Black Diagonal Package Design are all trademarks of Stanley Black Decker Inc or an affiliate thereof ...