Call Back-up Configuration
WPIM-S/T User’s Guide
3-17
3.
Use the arrow keys to highlight the SAVE command. Press ENTER.
The message “Save Done!” displays and Local Management saves the
changes to memory. Upon saving this screen, the interface just
configured is assigned to an application port (CKT#) in the table once
the device starts communicating with the service provider’s switch.
3.2.3
Configure Backup
Use the following Network Tools command to configure backup:
setbackup [PRIMARYIFACENUM] [BACKUPIFACENUM]
[TIMETOCONNECT] [TIMETODISCONNECT]
[CONNECTRETRIESNUM]
[TIMEBETWEENCONNETRETRIES][BACKUPOVERRIDE]
PRIMARYIFACENUM
The number of the primary interface that is going to be backed up.
BACKUPIFACENUM
The number of the interface assigned as the backup interface to the
primary interface.
TIMETOCONNECT
How long the system will wait (in seconds) before attempting to switch
over to the backup interface. Default is zero. Allowed values are in
increments of five seconds.
TIMETODISCONNECT
How long the system will wait (in seconds) before attempting to switch
over to the primary interface once the primary interface has been restored.
Default is 90 seconds. Allowed values are in increments of five seconds.
CONNECTRETRIESNUM
Specifies the number of tries to bring up the backup interface before
giving up. The default is three. Allowed values are in increments of one.
TIMEBETWEENCONNETRETRIES
Specifies the time interval between tries to bring up the backup interface.
The default is 30 seconds. Allowed values are in increments of five
seconds. Zero is allowed but not advisable.
NOTE
The commands in the rest of the procedure are Network Tools
commands. Refer to the host platform manual for detailed
information on accessing Network Tools.