Chapter 3: Local Management
3-6
WPIM-S/T User’s Guide
The BoD Configuration field leads to a screen that allows setting and
configuring MLP (Multilink Protocol) support. This screen is described in
Section 3.1.3
.
The following defines the fields in the Remote Profile Selection(s):
IF# (Read-Only)
Interface number of the profile.
Name (Read-Only)
Name of the profile as defined by the user in the Remote Profiles Setup
screen.
RID (Read-Only)
Remote Identifier. This is the index number of the Profile.
PF # (Read-Only)
Profile number, the information used to describe a possible connection.
SAVE (Command)
Used to save the configuration in memory once changes have been made.
CLEAR (Command)
Used to clear an entire selected profile.
SELECT (Command)
Used to enter the Remote Profile Selection(s) area in order to choose the
profile to configure or modify.
EXIT (Command)
Used to exit the current screen.
PREV/NEXT (Command)
The Remote Profile Selection(s) screen will not display more than 10
profiles at a time. When there are more than 10 profiles to be displayed,
the choices PREV and NEXT will display at the bottom of the screen.
Highlight NEXT to go to the screen after the currently displayed screen,
and PREV to go to the screen before the currently displayed screen. There
is a maximum of 20 profiles.