A-8
Technical Specifications
Figure A-3. FE-100FX
The transmitter power levels and receive sensitivity levels listed
are Peak Power Levels after optical overshoot. A Peak Power
Meter must be used to correctly compare the values given above to
those measured on any particular port. If Power levels are being
measured with an Average Power Meter, add 3 dBm to the
measurement to compare the measured values to the values listed
above.
Table A-6. Transmitter Power
Cable Type
Worst Case Budget
Typical Budget
50/125
µ
m fiber
6.0 dB
9.0 dB
62.5/125
µ
m fiber
9.0 dB
12.0 dB
100/140
µ
m fiber
15.0 dB
18.0 dB
FE-100FX
SP
Summary of Contents for SmartSTACK 10 ELS10-26
Page 2: ......
Page 10: ...viii Contents ...
Page 48: ...2 16 Unpacking and Installing Your ELS10 26 ...
Page 92: ...5 8 ELS10 26 Diagnostics and Troubleshooting ...
Page 112: ...B 12 Glossary ...
Page 116: ...Index I 4 W wiring crossover A 6 straight through A 5 ...