9T125-24 Module Specific Information
28
CLEAR
A command that only appears when you select ACCUMULATE as a statistic
reporting method. The CLEAR command allows you to manually reset the
screen’s statistics to zero and then start to accumulate statistics from that point in
time. For example, you may have accumulated statistics for 45 minutes, but now
you want to see accumulated statistics for the current period. In this case you
would position the cursor onto the CLEAR command and press the Space Bar.
The screen’s statistics will reset to zero and start to accumulate again.
RETURN
Allows you to exit the 9T125-24 Switch Statistics Screen.