27
9T125-24 Module Specific Information
Switch Statistics Screen Commands
TOTAL / ACCUMULATE / DELTA (Toggle)
Allows you to:
•
Display a running TOTAL of statistics (statistics since the module was inserted
into the chassis).
•
Reset the statistics to zero and then ACCUMULATE and display figures from
that point in time forward.
•
Display statistics and then reset the statistics to zero each time the screen is
refreshed (DELTA).
Table 5 shows the various statistics after four screen refreshes:
Press the Space Bar to toggle to the desired value, then press the Return key.
FNB / TOKEN RING 1/TOKEN RING 2 (Toggle)
Allows you to select the interface for which statistics are displayed.
•
If you select FNB, statistics for the FDDI interface are displayed.
•
If you select TOKEN RING 1, statistics for the module’s number one token ring
interface are displayed.
•
If you select TOKEN RING 2, statistics for the module’s number two token ring
interface are displayed.
•
Press the Space Bar to toggle to the desired value, then press the Return key.
REFRESH (Toggle)
Allows you to select the interval at which the screen will be updated (the range is
3 - 99 seconds). To increase the amount of seconds, press the Space Bar while the
cursor is on the command. To decrease the amount of seconds, press the Back
Space
key while the cursor is on the command.
Table 5. Statistics After Four Refreshes
After 1st
Screen Refresh
After 2nd
Screen Refresh
After 3rd
Screen Refresh
After 4th
Screen Refresh
TOTAL
1623
1636
1685
1712
ACC
0
13
62
99
DELTA
0
13
49
27