3-7
Switch Hardware
Table 1.1 describes the RS-232 serial port pinouts that are illustrated in
Figure 3.5.
3.2.2.1.3
Ethernet 10BaseT Port
The Ethernet 10BaseT port on the front panel of the SCP has a standard RJ45
connector. There is a transmit LED to the left of this port and a receive LED to
the right of this port. Tables 1.2 and 1.3 describe the states of the LEDs and
their meanings.
Table 3.1 -
RS-232 Serial Port Pinouts
Pin Number
Signal
Mnemonic
Signal Name
1
DCD
Data Carrier Detect
2
RXD
Receive Data
3
TXD
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Signal Ground
6
DSR
Data Set Ready
7
RTS
Request to Send
8
CTS
Clear to Send
9
Not Used
Table 3.2 -
Ethernet 10BaseT Transmit LED Description
LED Color
Meaning
red
There is a collision on the port.
green
The port is transmitting normally.
Table 3.3 -
Ethernet 10BaseT Receive LED Description
LED Color
Meaning
red
The port is failing link integrity.
green
The port is receiving normally.