A-5
Troubleshooting
A.1.4 Hardware Detected by Driver
To determine if the driver software on the host has detected the presence of an
ATM adapter board, issue the following command once the host system has
come up completely:
netstat -i
If the driver has located the ATM board, the screen output shows
fa0
in
response to the
netstat
command. If there is more than one adapter card, the
next board will be named
fa1
, and so on. If you have configured a Classical IP
interface, this will also be shown. The option
-i
shows the state of interfaces
that were auto-configured, as happens when the Cabletron software is loaded
and run upon system boot. Interfaces statically configured in a system, but
not located at boot time, are not shown.
If the driver does not see the ATM board, no response will be given. Reseat
the board by performing the following steps to ensure that failure was not
due to improper insertion of the board:
1.
Halt the system, being sure to follow the procedures outlined in
Chapter 2 of the User’s Manual for the adapter.
2.
Open the computer as shown in Chapter 2 of the User’s Manual
for the adapter, and reseat the board.
3.
Reboot the system.
If the board still fails after a reseat, then it should be returned for repair. Call
Cabletron Systems’ Technical Support for further assistance.
Summary of Contents for MMAC-Plus 9A000
Page 1: ...MMAC Plus 9A000 SFCS 200BX SFCS 200WG and SFCS 1000 ATM SWITCH User s Guide...
Page 2: ......
Page 17: ...1 3 Introduction Figure 1 1 9A000 Switch Configuration...
Page 22: ...1 8 Introduction...
Page 26: ...2 4 Installing the 9A000...
Page 50: ...3 24 Switch Hardware...
Page 84: ...5 18 Hardware Maintenance Procedures...
Page 157: ...C 31 Hardware Specifications...
Page 158: ...C 32 Hardware Specifications...
Page 180: ...g 22 GLOSSARY...