C-18
Hardware Specifications
C.2.10 622 Mbps OC-12c/STM-4c SM Module
The following specifications apply to network module NM-1/622SMIRC:
Description
Specification
Port Capacity
One SONET/SDH port per module
Data Rate
622.08 Mbps
Output Buffer
13,312 cell capacity
Media
Single mode fiber
Max. Line Length
~14 km
Connectors
FC
Line Encoding
Non-Return to Zero (NRZ)
Framing
STS-12c/STM-4c
Clock Accuracy
±
20 ppm
Timing
Primary and secondary 8kHz reference from
internal (default) or network
Loopbacks
Transmit and receive loopbacks
Power
-8 to -15 dBm transmit power, -8 to -28 dBm
receive sensitivity, 0 to 13 dB path attenuation
Core Diameter
10
µ
m
Fiber Diameter
125
µ
m
Wavelength
1310 nm
Statistics/Alarms
SONET/SDH statistics include Loss of Signal
(LOS), Loss of Frame (LOF), Loss of Pointer
(LOP), Far End Block Errors (FEBE), Alarm
Indication Signal (AIS), Far End Receive Fail-
ure (FERF), Yellow Alarm, Bit Interleaved Par-
ity errors (Line BIP-24, Section BIP-8, Path
BIP-8), Header Check Sequence errors (HCS),
cells received (RxCells), cells transmitted
(TxCells)
Compliance
ATM Forum STS-12c UNI v3.1, ITU-T I.432,
ANSI T1E1.2/93-020, T1S1/92-185, ITU-T
G.957, Bellcore TR-NWT-000253
Summary of Contents for MMAC-Plus 9A000
Page 1: ...MMAC Plus 9A000 SFCS 200BX SFCS 200WG and SFCS 1000 ATM SWITCH User s Guide...
Page 2: ......
Page 17: ...1 3 Introduction Figure 1 1 9A000 Switch Configuration...
Page 22: ...1 8 Introduction...
Page 26: ...2 4 Installing the 9A000...
Page 50: ...3 24 Switch Hardware...
Page 84: ...5 18 Hardware Maintenance Procedures...
Page 157: ...C 31 Hardware Specifications...
Page 158: ...C 32 Hardware Specifications...
Page 180: ...g 22 GLOSSARY...