NETWORK REQUIREMENTS/SPECIFICATIONS
2-5
BNC IN'IREFACE
Internal Transceiver:
Cabletron Systems' TMS-3™
Transceiver.
Type:
BNC receptacle, with gold center
contact, for use with BNC type
tee-connectors and RG-58 thin-net
cable.
ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
+5
°
to +40
°
C (+41
°
to +104
°
F)
Non-operating Temperature: -30
°
to +90
°
C (-22
°
to +160
°
F)
Operating Humidity:
5 to 95% (non-condensing)
SAFETY
Designed in accordance with UL478, UL910, NEC 725-2(b), CSA,
IEC, TW, VDE class A. Meets FCC part 15, Class A limits.
WARNING
: It is the responsibility of the person who sells the system of
which the IRM will be a part to ensure that the total system meets allowed
limits of conducted and radiated emissions.
SERVlCE
MTBF (MHBK-217):
>150,093 hrs. projected
MTTR
<0.5 hr.