Page 14
Model 64/64x2 Instruction Manual
MENU-SELECTED FUNCTIONS
Up/Down Arrows
The Up and Down arrows are used to select menu functions, scrolling through wire list programs
and making selections within other functions.
Menu Run
The MENU RUN key is used to execute the menu function that is selected by the Up/Down
arrows and shown on the display. The MENU RUN key also is used as an advance key for the
menu function.
The fourteen menu-selected functions are as follows:
Learn Known Good
Save Internal
Save Cartridge
Delete Internal
Delete Cartridge
Clear Memory
Set Baud Rate
Print Wire List
Print User List
Load Internal
Load Cartridge
Loop Test
Search
Self Test
NOTE: Functions in left column require use of ENABLE plug.
To select a menu function, use the following standard procedure:
1.
Press Up or Down arrow to step through the menu until the desired function is
displayed.
2.
Insert the ENABLE plug if the function is one listed in the left column above.
3.
Press MENU RUN to initiate the function.
Learn Known Good
This function is used for scanning existing continuities in a sample assembly and storing them as
a program in the working memory. As a program is stored, it writes over any program currently
in the working memory. User Labels, however, are maintained if they are currently loaded in
memory. Labels can be cleared before learning by first selecting the Clear Memory function.
(To save the current program, use the Save Internal or Save Cartridge function, described in a
later paragraph, before using Learn Known Good.)
Summary of Contents for 64
Page 1: ...CONTINUITY TESTER ASSEMBLY AID MODEL 64 MODEL 64x2 Cablescan ...
Page 2: ......
Page 51: ...Model 64 64x2 Instruction Manual Page 43 Figure 8 Schematic Model 64 CPU Board 2 of 3 ...
Page 52: ...Page 44 Model 64 64x2 Instruction Manual Figure 8 Schematic Model 64 CPU Board 3 of 3 ...
Page 53: ...5900384 Rev D Cablescan ...