18
Water System Parts
One of the key features to the CabKing-6V3
is the single pass, contamination-free water
system. The water system will remain trouble-
free as long as you use a fresh, clean supply
of water. Do this by using a separate intake
water bucket from the drainage bucket. A
fresh supply of water will protect you from
cross-contamination of grit which can occur
in recirculating systems that use a bubbler
or geyser. With fresh water, the pump and
intake tubes will stay clean and unobstructed
so there will be enough water pressure. The
water pump is rated at 30 watts, 605GPH,
8.2ftHmax. We recommend using a minimum
5 gallon bucket for both the water pump and
drainage. You will typically go through an
average of 1-2 gallons of water per hour, with
the water control knobs on a light to medium
drip. Monitor the water level in the bucket
to make sure the water pump is always
submerged in water. THE WATER PUMP
SHOULD NOT BE RUN DRY. UNPLUG WATER
PUMP FROM POWER SOURCE WHEN NOT IN
USE.
By design, all water system parts can
be easily disassembled by pulling off or
unscrewing and cleaned with soapy water.
For routine maintenance, keep the nozzles,
Y-split and tubing clean with a small wire
brush or the included pipe cleaner.
DO NOT SET-UP THE WATER SYSTEM AS A
RECIRCULATING SYSTEM. THIS WILL VOID
YOUR WARRANTY. This means putting the
drip pan tubes into the same bucket of water
as your water pump. Doing so will void your
warranty and you also risk cross-contamination
of grit, which may result in scratches on your
stone. The grit will eventually build up in the
water control valves, nozzles and tubing which
will restrict water flow and potentially clog the
water system parts.
Underneath each hood are three Y-splits with
two nozzles in each, three needle valves and
clear tubing that connects to each needle
valve. The clear tubing measures 1/4" outer
diameter x 1/8" inner diameter. See image
below to identify parts.
Y-split
Clear tubing
Nozzle
Needle valve