![background image](http://html1.mh-extra.com/html/cab/wicon-squix/wicon-squix_service-manual_3233235013.webp)
13
3.7
Replacing the PCB Control
1
2
1
1
1
Fig. 13
Replacing PCB Control
Loosen four screws (1).
Pull-out all cables from the connectors of the PCB Control (2).
Pull the PCB Control out of the housing.
Mount the new PCB in the opposite order.
10
9
8
7
4 5
6
3
13
12
11
Fig. 14
PCB Control - connectors
Pos. Connector
Lettering
3
Periphery
Periphery
4
LP Sensor Centering gear side
Centering L
5
LP Sensors ReDiameter
Ref+Dia
6
LP Spring Contact
Spring contact
7
LP Sensor Touchguard
Touchguard
8
Service Button
Service1
9
Sensor Applicator Locked
Swingoff
10
Ventilator
Fan
11
Motor Touchguard
Touch-Motor
12
LP Sensor Centering winder side
Centering R
13
Motor Winding
Drum-Motor
Table 1