cab - Produkttechnik GmbH
B-5
Pin Assignment of the Peripheral Connector for Non-cab-Applicators
Hermes has a 15 pin SUB-D plug at the rear side. The signal set of this
interface includes on the one hand the signals needed to couple a non-cab-
applicator and on the other hand status signals of the warning sensors "label
end" and "ribbon end".
All inputs and output are potential-free.
CAUTION !
This interface is not designated to couple a cab-applicator.
For the use of cab-applicators the Hermes printers have an additional
interface with a 15 pin SUB-D socket at the front side.
Fig. B-7 Plug of the Peripheral Connector
Table B-3 Pin-Assignment of the Peripheral Connector Plug
Pin 1
Pin 8
Pin 15
Pin 9
Pin
Direction
Description
1
output
printer not ready
2
output
label is printed
3
output
printer error
4
output
print job available
5
output
green (device is switched on)
6
input
external error
7
input
label was taken
8
input
print start
9
output
warning transfer ribbon end
10
(output)
reverse line (for all output signals)
11
output
warning label end
12
output
label in present position
13
(input)
external error (reverse line)
14
(input)
label was taken (reverse line)
15
(input)
print start (reverse line)