30
30
Measuring point (MP S) for Supporting Air.
1
2
3
MP S
With a Manometer that is capable of measuring pressures
ranging from -7 to 7 bar the effective pressures can be
measured.
MP S: Support air (desired default value 2 bar)
1. Remove the cover and interpose the manometer at the
MP S .
- Tube (3) from the vent block to the blowtube connection.
- Connection (2) to the blowtube.
2. Measure the air pressure by pressing the micro switch (1)
to raise the magnetic valve while the air pressure feed is
open.
3. If required set the air pressure as needed via the throttle
valve.
4. Remount cover.
Fig. 29
Measuring point for supporting air- picture without pressure reduce valve
!
Attention!
After measuring the pressure ensure that the connections to and from the air pressure are securely fastened
back in place.
6.9
Adjustment on the Pressure Reduce Valve Cylinder Flag
2
3
MP P
1
With a Manometer that is capable of measuring pressures
ranging from -7 to 7 bar the effective pressures can be
measured.
MP P: Pressure (desired default value 2 bar)
Remove the cover and interpose the manometer at the
MP P.
- Tube (3) to the pressure reduce valve.
- Push-in Connector (2) on the pressure reduce valve
5. Run cycles
. „4.1 Test Mode without a Print Job“.
Check the pressure when closing the pads.
6. If necessary, set pressure on the regulator (1).
7. Mount the cover.
Fig. 30
Measuring point for the pressure on the pressure reduce valve to cylinder flag
!
Attention!
After measuring the pressure ensure that the connections to and from the air pressure are securely fastened
back in place.