Copyright © 2011 Shenzhen C2S Technology Co., Ltd. All rights reserved.
Example is to change the default password 1234 to be 888888.
Example Command:
*1234*E888888#
Example reply:
Password has been changed!
Note:
-
The maximum password length is 6 digits. And no characters acceptable;
-
Anyone with correct access password and right command format, device will send response.
7.1.5 Recover factory defaults setting:
Function
SMS Command Format
Device Reply SMS
Recover factory Setting
*UPWD*V#
Factory Setting Recovered
Example Command:
*1234*V#
Example Reply:
Factory Setting Recovered
Note:
-
After device receives this command, device will setup all settings to be factory defaults
parameters.
Factory defaults setting are as following:
①
Time-based Data Report Interval: 60Seconds
②
Distance-based Data Report Interval: 500Meters
③
Angle-based Data Report Interval: 30Degrees
④
ACC ON/Off Report: ON
⑤
IP,Port, APN, username and password: Empty
⑥
Authorized Numbers A/B/C/D/G: Empty
⑦
Default Password: 1234
⑧
GEO Fencing Areas: Empty
⑨
Speed Over Limit: 0 ( Off)
⑩
Data Report when ACC Off: Off
⑪
Memory Records time interval: 5Minutes
⑫
Towing Alarm: ON
⑬
Buzzer Sound: Off
⑭
Incoming Call auto pickup: Off
⑮
Working Mode: SMS+GPRS
⑯
SMS Data Time: GMT Time
⑰
Sleep mode when ACC Off: Simple Sleep
-
Device will reboot itself after this command applied.
7.1.6 Setup Speed over Limit value:
Function
SMS Command Format
Device Reply SMS