![C.Plath NAVIGAT X MK 1 Mod. 10 Operator'S Manual Download Page 59](http://html1.mh-extra.com/html/c-plath/navigat-x-mk-1-mod-10/navigat-x-mk-1-mod-10_operators-manual_3123976059.webp)
Page 5-15
NAVIGAT X MK 1 Mod. 10 / SR-180 MK 1 Mod. 10
056310
3-149 MK110ENG.P65
1)
De-energize the gyrocompass system.
2)
Wait at least 45 minutes for the gyro-
scopes to stop rotating.
3)
Unscrew the retaining screws of the com-
pass housing door and take the door off
the housing.
5.3.4
Removal of the Gyrosphere
4)
Disconnect the grounding strap between
door and housing. If the control and dis-
play unit is mounted in the door, unplug
the unit's connector from the masterboard
(plug connector J3).
5)
Place the door aside.
6)
Disconnect the plug from the socket on
the gyrosphere container.