Page 4-13
NAVIGAT X MK 1 Mod. 10 / SR-180 MK 1 Mod. 10
056310
3-149 MK110ENG.P65
SERVICE SETUP 1
F1 EXT. STATUS IN
F2 NAME OF GYRO
F3 TEST MODE
...
.
.
.
.
.
.
.
.
.
.
.
.
.
SERVICE SETUP 1
F1 INTERFACE I/O
F2 ANALOG ROT OUTP
F3 FEEDBACK SIGNALü
...
.
. ..
.
.
.
...
.
.
.
.
.
.
.
.
FEEDBACK SIGNAL
rudder angle feedback inputs
NO. OF RUDDERS
1 / 2
SET. RUDDER 1
scale: 0.1 – 99.9 mV/°
offset: -9.9° – +9.9°
SET. RUDDER 2
scale: 0.1 – 99.9 mV/°
offset: -9.9° – +9.9°
EXT. STATUS IN
Stat. LOG
Stat. HDG +180°
SHAFT COR. ANGLE
-180.0° – +180.0°
° –
SYSTEM TYPE
TEST MODE
SERVICE SETUP 1 û
F1 SYSTEM TYPE
F2 ALIGN ERR. CORR.
F3 SHAFT.COR.ANGLEü
...
.
. .
.
.
.
.....
.
.
.
.
.
.
gyro ID
function ext. status input
alignment error correction angle
system type settings
shaft encoder correction angle
2
3
type G
type GM
type GG
type GGM
ALIGN ERR. CORR.
-180.0° – +180.0°
° –
rate of turn: -999 – +999°/min
scale: 0.1 – 999.9 mV/°/min
heading: 0.0 – 359.9°
contd. from previous page
hdg. sel. INT/G
hdg. sel. INT/GG
h
dg. sel. EXT
hdg. sel. NSD
NAME OF GYRO
gyro ID.: 1/2/3
test mode
2
3