Over temperature safety detection:
• To comply with international safety regulations, the glue tank and the drum are equipped
of temperature regulation circuitry. The system stops the machine if the glue
temperature exceeds 170°C either on one or on other sensors.
This system requires a working temperature below 165°C and a glue flash point higher
than 200°C.
• After the system activated, the machine shut down and the binder restart could only be
done by a technician.
Note : • Please refer to the safety data sheet (in appendix) for the National Coolbind
1300.
• If an other type of glue is used of the recommended one (National Coolbind
1300), please refer to the safety data sheet of the used glue.
• Vapours which may be formed at elevated temperature may be irritating to
eyes and respiratory tract. A local exhaust over glue tank and a good
ventilation of the room are required.
• Different fume regeneration/extraction are available following the type of
binder (see spare parts catalog).
Operator Manual
Page 9 - 30
Initial issue: 12/00
Latest revision: 08/06
Summary of Contents for Bourg Binder 3001
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 49: ...Operator Manual Page 9 43 Initial issue 12 00 Latest revision 11 01 NOTES...
Page 50: ...Operator Manual Page 9 44 Initial issue 12 00 Latest revision 11 01 NOTES...
Page 51: ...Operator Manual Page 9 45 Initial issue 12 00 Latest revision 11 01 NOTES...