False ceiling-mounted motion detector

C-LOGIC 650-MD

SKU: CLOGIC650MD230VCBINT

INSTRUCTIONS MANUAL

ENGLISH 

EN

The sensor is an active motion detector, it emits high-frequency electro-magnetic wave 

(5.8GHz) and receives their echo. The sensor detects the change in echo from even the 

slightest movement in its detection zone. A microprocessor then triggers the “switch light 

ON” command. Detection is possible through doors, panes of glass or thin walls.

SPECIFICATION:

•  Power supply: 220-240VAC      

•  Power frequency: 50/60Hz 

•  Installation sit: Indoors, ceiling mounting

•  HF system: 5.8GHz CW radar, ISM band

•  Transmission power: <10mW

•  Rated load:

 - Incandescence: 1200W

 - Fluorescence: 300W

 - LED: 300W

•  Detection angle: 360°

•  Reach: 1-10m radius, adjustable

•  Time setting: 8sec to 12min

•  Light control: 2~2000LUX

•  Power consumption: approx.0.9W

Important: persons or objects moving towards the sensor are detected best.

NOTE: the high-frequency output of this sensor is <10Mw- that is just one 100th of the 

transmission power of a mobile phone or the output of a microwave oven.

Reach setting (sensitivity)

Reach is the term used to describe the radii of the more or less circular detection zone pro-

duced on the ground after mounting the sensorlight at a height of 2.5m, turn the reach con-

trol fully anticlockwise to select minimum reach (approx.1m radii), and fully clockwise to se-

lect maximum reach (approx. 10m radius).

NOTE: the above detection distance is gained in the case of a person who is between 

1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if person’s 

stature, figure and moving speed change, the detection distance will also change.

Time setting

The light can be set to stay ON for any period of time between approx. 8sec(turn fully anti-

clockwise) and a maximum of 12min(turn fully clockwise). Any movement detected before 

this time elapse will re-start the timer. It is recommended to select the shortest time for ad-

justing the detection zone and for performing the walk test.

NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start detect-

ing movement again. The light will only switch on in response to movement once this pe-

riod has elapsed.

Light-control setting

The chosen light response threshold can be infinitely from approx. 2-2000lux. Turn it fully 

anti-clockwise to select dusk- to-dawn operation at about 2 lux. Turn it fully clockwise to se-

lect daylight operation at about 2000lux. The knob must be turned fully clockwise when ad-

justing the detection zone and performing the walk test in daylight.

TROUBLESHOOTING

Malfunction

Cause

Remedy

The load will not 

work

Wrong light-control setting selected

Adjust setting

Load faulty

Change load

Mains switch OFF

Switch ON

The load work  

always

Continuous movement in the detection zone

Check zone setting

The load work  

without any  

identifiable 

 

movement

The sensor not mounted for detecting  

movement reliably

Securely mount enclosure

Movement occurred, but not identified by the 

 

sensor (movement behind wall, movement of a 

small object in immediate lamp vicinity etc.)

Check zone setting

The load will not 

work despite  

movement

Rapid movements are being suppressed to  

minimize malfunctioning or the detection zone 

you have set is too small

Check zone setting

COVERAGE ADJUSTMENT

 

1-10m radii

TIME SETTING

 

8sec~12min

LUX ADJUSTMENT

 

2~2000LUX

                              

CONNECTION-WIRE DIAGRAM

N

L'

L

                                                              

Connect N, L with power; Connect N, L’ with load.

INSTALLATION

Place the detector above the false ceiling, with the flat side resting on the false ceiling.

MANUFACTURER:

MGL International

APAC: 

MGL GLOBAL SOLUTIONS LTD

[email protected]

Flat 4-1, 4/F, No. 35, Section 3 Minquan 

East Road. Taipei, Taiwan.

Tel: +886 2-2508-0877

EMEA: 

MGL EUMAN S.L.

[email protected]

Parque Empresarial Argame, 33163 

Morcín. Asturias, Spain.

Tel: +34 985-08-18-70

AMERICAS: 

MGL AMERICA, LLC.

[email protected]  

US East Coast:

 2810 Coliseum Centre 

Drive, Ste. 100. Charlotte, North Carolina, 

28217 USA

Tel: +1 833 533-5899

US West Coast:

 760 Challenger Street. 

Brea, California 92821 USA

Tel: +1 310-728-6220

www.mgl-intl.com

Summary of Contents for 650-MD

Page 1: ...de detección y para la realización de la puesta en marcha NOTA después de que la luz se apague tarda aprox 1 segundo antes de que sea capaz de empezar a detectar movimiento de nuevo La luz sólo se enciende en respuesta al mo vimiento una vez que este periodo ha transcurrido Configuración del control de luz El umbral de respuesta a la luz elegida puede ser desde 2 hasta 2000 luxes Gire el mando com...

Page 2: ...recommended to select the shortest time for ad justing the detection zone and for performing the walk test NOTE after the light switches OFF it takes approx 1sec before it is able to start detect ing movement again The light will only switch on in response to movement once this pe riod has elapsed Light control setting The chosen light response threshold can be infinitely from approx 2 2000lux Tur...

Page 3: ...ndable sélectionner le temps le plus court pour régler la zone de détection et pour la réalisation de la mise en service NOTE après que la lumière est éteinte il prend environ 1 seconde avant d être capable de commencer à détecter au nouveau le mouvement La lumière seulement s allume en ré ponse au mouvement et après que ce délai est passé Configuration du contrôle de lumière La valeur de seuil de...

Page 4: ...comendado selecionar o menor tempo para ajustar a zona de detecção e para a realização da posta em marcha NOTA depois que a luz se desligar demora aproximadamente de 1 segundo antes que seja capaz de começar a detectar movimento de novo A luz só acende em resposta ao movi mento depois de decorrido este periodo Configuração do controlo de luz O limiar de resposta à luz escolhida pode ir dos 2 até o...

Reviews: