5.BATTERY & FUSE REPLACEMENT

If "E!l"appears on display, it indicates that the battery 

should be replaced. 

Fuse rarely need replacement and blow almost always as 

a result of operator's error. 

To avoid electrical shock,  Remove test leads before 

opening battery or fuse cover. 

To prevent fire,  Install quick acting fuse with amp/ volt 

rating  shown: 

F1 :FF 400mA H 600V  F2:FF 10A H 600V 

To replace fuse remove the 2 screws in the bottom of the 

case. To replace battery remove the 1 screws of the battery 

cover.Simply remove the old, and replace with a new one. 

Be careful to observe battery polarity. 

&warning 

Before attempting to open the case,always be sure 

that test leads have been disconnected from 

measurement circuits. Close case and tighten 

screws completely before using the meter to avoid 

electrical shock hazard. 

5.1 Accessories 

1.0perator's instruction manual 

1 pcs 

2.Set of test leads

1 pcs 

3.Gift box

1 pcs 

4.9 volt battery

1 pcs 

1 pcs 

5.K-type temperature probe(P3400)