4.3 Resistance measurement
1.Connect the red test lead to
"V.0.mA"
jack and black
test lead to the
"COM"
jack. (The polarity of red lead is
positive "+".)
2.Set the rotary switch at desired"Q"range position.
3.Connect test leads across the resistor to be measured
and read LCD display.
4.lf the resistance being measured is connected to a
circuit.turn off power and discharge all capacitors
before applying test probes.
4.4 Diode test
1.Connect the red test lead to
"V.Q.mA"
jack and the
black test lead to the
"COM"
jack (The polarity of red
lead is positive "+").
2.Set the rotary switch at "*"position.
3.Connect the red test lead to the anode of the diode to
be tested and the black test lead to the cathode of the
diode.The approx.forward voltage drop of the diode
will be displayed.If the connection is reversed,only
figure "1 "will be shown.
4.5 Audible continuity test
U
se the"FUNC"key to enter to the continuity mode.
1.Connect red test lead to
"V.Q.mA",
black test lead to
"COM".
2.Set range switch to"••I) "position.
3.Connect test leads to two points of circuit to be tested.
If continuity exists, built-in buzzer will sound.
11
4.6 Measuring temperature
1.lf you use
°
C function.set the rotary switch at
°
Cposition.
If you use
°
F function.set the rotary switch at °F Position.
When shorted two test probe.The LCD display will show
the current environment temperature.
2.Connect the red lead of "K" type thermocouple into the
"V.Q.mA"
jack and the black lead of
"K"
type
thermocouple into the
"COM"
jack.
3.Read temperature value on the LCD display.
&warning
To avoid electric shock,be sure the thermocouple
has been removed before changing to another
function measurement.
4.7 Non-contact voltage detection
When the meter head closed to the AC voltage field.the
LED
lighted the closed distance is about 30mm from the
AC voltage field.
&warning
Even without LED indication,the voltage may still
exist.Do not rely on non-contact voltage detector to
determine the presence of voltage wire,Detection
operation may be subject to socket design,
insulation thickness and different type and other
factors.