Document:
Date:
Created By:
INSTALLATION INSTRUCTIONS
C-SW-A-S66L-SCCT-US-UC Series
http://lighting.cree.com/warranty | 866.924.3645
LPN00869X0001A0_A
1-04-2022
TMT
9.
Select the desired CCT and fixture wattage using the DIP switches.
See
Figure 5.
10.
Wire fixture per the appropriate
Electrical Connections
section.
NOTE:
Dimming of the fixture will be controlled by the occupancy
sensor.
11. Rotate the optics panel back up into position and reinstall screws
that were removed in Step 2 to retain panel. See
Figure 6
.
12.
Reinstall lens on fixture. Start at one end of the fixture and
squeeze lens to allow slots in lens to engage with flanges on
fixture. Work down toward opposite end of fixture until lens is fully
retained. See
Figure 7
.
NOTE:
Pull on lens to make sure it is properly retained.
13.
Supply power to fixture.
14. Refer to Ultrasonic Occupancy Sensor- Operation and
Programming to properly configure sensor.
Wattage Switch
CCT Switch
3500K-5000K
55W 45W 35W
FIGURE 5
FIGURE 6
FIGURE 7
NOTE:
Factory settings are 55W, 5000K