background image

21/08/2019 

11 

 

11

 

Disclaimer 

Care has been taken in the preparation of this manual to give instructions of relevance to normal 
use of the product. All advice, analysis, calculations, information, forecasts and recommendations 
are  supplied  for  the  assistance  of  the  user  and  are  not  to  be  relied  on  as  a  substitution  for  the 
exercise of judgement by the user. C-Tech Innovation Ltd does not accept liability for any direct or 
consequential  loss  arising  from  use  of  this  manual  or  its  contents  and  gives  no  warranty  or 
representation  (express  or  implied)  as  to  the  fitness  for  the  purpose  of  any  process,  material, 
product or system referred to in the manual. 

 

 

 

 

All rights reserved.  No part of this publication may be reproduced or transmitted in any form or 
by any means electronic, mechanical, photocopied, recorded or otherwise, or stored in any 
retrieval system of any nature without the written permission of the copyright holder. 

 

 

 

 

Summary of Contents for LAB 1x1

Page 1: ...21 08 2019 1 C Flow LAB 1x1 Instruction Manual...

Page 2: ...Contents 1 Introduction 3 2 Safety 4 3 Unpacking 4 4 Specifications 5 5 Assembly Instructions 6 6 Parts List and Exploded View 7 7 Troubleshooting 9 8 Cleaning 9 9 Templates 9 10 Other C Flow Product...

Page 3: ...d is shown in the on line video demonstration The unit is designed for ease of use and no tools are required for assembly The cell comes equipped with a set of electrodes but it is designed so that yo...

Page 4: ...r measure the pressure at the entrance to the cell and restrict the liquid flow rate so that the pressure does not exceed 1 bar gauge The user should check the pressure rating of any tubing or fitting...

Page 5: ...x 10 mm Electrode material carbon supplied as standard Current collectors brass Electrolyte ports PEEK Reference electrode blanks PEEK Cell Frames CPVC Gasket material EPDM Membrane material not suppl...

Page 6: ...tional Fit Membrane Gasket Membrane and second Membrane Gasket The purpose of the Membrane Gaskets is to locate a Membrane if used Fit O Ring into face of Front Frame and fit the Front Frame over the...

Page 7: ...Current Collector 2 9 Electrode 2 10 Electrode Gasket 2 11 Reference Electrode Port Plug 2 12 Electrode Port 1 8 4 13 Electrode Port 1 16 2 14 Back Frame 1 15 O Ring ID 40 95 Dia 2 62 1 16 Membrane G...

Page 8: ...21 08 2019 8...

Page 9: ...ow Rate Check piping not kinked Poor Electrical Contact Check Current Collector face is clean and bright Use solvent and or gentle abrasive Check rear side of electrode is clean Use solvent and gentle...

Page 10: ...cess development in industry or academia A wide variety of electrochemical processes can be carried out on C Flow PLT including the treatment of dilute systems e g waste water chemical synthesis visco...

Page 11: ...h Innovation Ltd does not accept liability for any direct or consequential loss arising from use of this manual or its contents and gives no warranty or representation express or implied as to the fit...