Specifications 

 

Height 

110 mm 

Width 

100 mm with fittings 

Depth 

150 mm with fittings 

Weight  

1.25 kg  

End plates 

304 stainless steel 

Electrode gap 

10 mm 

Electrode dimensions 

20 mm x 20 mm for working electrode area of 10 mm x 10 mm 

Electrode material 

carbon supplied as standard 

Current collectors 

brass 

Electrolyte ports 

PEEK 

Reference electrode blanks 

PEEK 

Cell Frames 

CPVC 

Gasket material 

EPDM 

Membrane material 

not supplied 

Electrode gasket material 

expanded EPDM 

O-rings 

EPDM 

Stand 

polypropylene 

Gasket templates 

stainless steel 

Maximum applied voltage 

10 V 

Operating temperature 

up to 80°C 

Throughput 

depending on fluid properties 

Pressure 

up to 1 bar (g) 

 

 

 

Summary of Contents for LAB 1x1

Page 1: ...21 08 2019 1 C Flow LAB 1x1 Instruction Manual...

Page 2: ...Contents 1 Introduction 3 2 Safety 4 3 Unpacking 4 4 Specifications 5 5 Assembly Instructions 6 6 Parts List and Exploded View 7 7 Troubleshooting 9 8 Cleaning 9 9 Templates 9 10 Other C Flow Product...

Page 3: ...d is shown in the on line video demonstration The unit is designed for ease of use and no tools are required for assembly The cell comes equipped with a set of electrodes but it is designed so that yo...

Page 4: ...r measure the pressure at the entrance to the cell and restrict the liquid flow rate so that the pressure does not exceed 1 bar gauge The user should check the pressure rating of any tubing or fitting...

Page 5: ...x 10 mm Electrode material carbon supplied as standard Current collectors brass Electrolyte ports PEEK Reference electrode blanks PEEK Cell Frames CPVC Gasket material EPDM Membrane material not suppl...

Page 6: ...tional Fit Membrane Gasket Membrane and second Membrane Gasket The purpose of the Membrane Gaskets is to locate a Membrane if used Fit O Ring into face of Front Frame and fit the Front Frame over the...

Page 7: ...Current Collector 2 9 Electrode 2 10 Electrode Gasket 2 11 Reference Electrode Port Plug 2 12 Electrode Port 1 8 4 13 Electrode Port 1 16 2 14 Back Frame 1 15 O Ring ID 40 95 Dia 2 62 1 16 Membrane G...

Page 8: ...21 08 2019 8...

Page 9: ...ow Rate Check piping not kinked Poor Electrical Contact Check Current Collector face is clean and bright Use solvent and or gentle abrasive Check rear side of electrode is clean Use solvent and gentle...

Page 10: ...cess development in industry or academia A wide variety of electrochemical processes can be carried out on C Flow PLT including the treatment of dilute systems e g waste water chemical synthesis visco...

Page 11: ...h Innovation Ltd does not accept liability for any direct or consequential loss arising from use of this manual or its contents and gives no warranty or representation express or implied as to the fit...

Page 12: ...21 08 2019 12 C Tech Innovation Ltd Capenhurst Technology Park Capenhurst Chester UK CH1 6EH Tel 44 0 151 347 2900 info ctechinnovation com www ctechinnovation com...

Reviews: