Error 0x9006 - EL Jam Error
1. If the Mobile Platform doesn’t physically move
Possible Causes:
•
7000 Controller
•
15 Amp Fuse
•
Motor Cable
•
Internal Wiring Harness
•
Elevation Motor or Belt
a.
Verify if 7000 Controller is outputting 24VDC. Disconnect the motor cable from the back of the
controller, place the volt meter leads on pins 1 and 3 of the controller. Using the 7000 controllers
front panel, select Elevation with HI SPEED on and hold +. Are you getting 24VDC?
b.
If no voltage is shown
, please turn off the controller and verify the 15A fuse has not blown. If the
fuse is blown replace it and try again. If the fuse is not blown, contact C-Com Technical Support for
further assistance.
Warning High Voltage:
Always remove power from the 7000 Controller prior to removing fuse.
Failing to do so can result in personal injury or damage to the controller.
DO NOT OPEN