background image

F

Uzzy

 l

ogic

™  co2 c

ontrol

o

vervieW

 

Most people who have used the XGC-1e, rate it the best combination controller available today. The fact that the built-in “Fuzzy Logic”

  

CO

2

 control system has redefined what true Part-Per-Million CO

2

 control is really about, may have something to do with it…

“s

upplemenTal

 co

2

Let’s talk about ... Carbon Dioxide. CO

2

 is present in relatively low quantities, (300-600 PPM) in your normal, generic, everyday air. But 

plant growth can be increased and accelerated if the level of CO

2

 is increased to, let’s say... 1000 -1500 PPM. For this reason, the XGC can 

control CO

2

 distribution for those people who prefer to use supplemental CO

2

There are some inherent dangers associated with using CO

2

. Here are some of the rules to remember when using CO

2

:

A)   Cylinders (bottles) of compressed CO

2

 should never be stored inside the growing area or anywhere else where the temperature may 

rise above 100º F.

B)   The growing area should not be occupied while CO

2

 is in operation.

C)   Do not enter the growing area until the CO

2

 has been exhausted.

D)   CO

2

 is heavier than air and will accumulate towards the ground.

E)   In high enough concentrations CO

2

 can kill!!!  The OSHA maximum “Personal Exposure Level” is 5000 PPM.

*Note:  The  XGC  CO

2

  control  system  can  be  used  for  both  compressed  CO

2

  cylinders,  and  generators.  The  CO

2

  receptacle  is  120vac. 

Compressed CO

2

 cylinders require an approved regulator / flow gage and a valve. 

If optimum CO

2

 “mileage” is desired, a self-contained air conditioner or other “Closed loop” cooling method is highly recommended. A 

closed loop system will regulate temperatures within the zone allowing you to extend the CO

2

 maximum cycle time thus reducing CO

2

 use 

dramatically.  

Another method of reducing heat build up includes utilizing “Ventilated light hoods”. Just be sure to make the ventilation system of the 
hood as airtight as possible so that your precious CO

2

 is not being drawn out of the area by the ventilated hood exhaust fan.

If sufficient CO

2

 is provided and the proper level of nutrients and light is available, a 35% increase in growth rate is possible. However if 

you suspect the higher temperatures are adversely affecting the plants, a shorter CO

2

 cycle may produce better results. Remember that 

a shorter CO

2

 cycle duration translates to increased CO

2

 usage. 

f

uzzy

 l

oGic

 co

2

 c

onTrol

Fuzzy Logic is a form of Artificial Intelligence (AI). It is as though a trained operator is there to monitor the level and release more CO

2

 only 

when required. It can also “learn” how to maintain the set point when it is first started by pressing a couple of buttons. It then calculates 
how to best maintain the CO

2

 level for any size space… automatically! 

a

uTo

-T

uninG

 co

2

Every growing area has variables such as area size, fan types, ambient temperature, unique airflow characteristics, CO

2

 delivery system 

and flow-rate. Ordinary “part-per-million” controllers do not take most of these variables into consideration thus they are not very good 
at keeping the CO

2

 at a constant level. A standard set of “parameters” which define how the Fuzzy Logic’s AI (Artificial Intelligence) is 

pre-programmed into the XGC-1e. For MOST applications, the standard set will work fine. In fact, most people report the XGC-1e maintains 
their desired se/- 15-25 PPM.    

 If after a few days of operating the XGC-1e you are not satisfied with the performance, you can try to allow the unit to “re-teach” itself the 
base parameters FOR YOUR SPECIFIC AREA. And that is exactly what the “Auto-Tuning” function does. When the “Auto-Tuning” function 
is used, the XGC-1e automatically measures your systems performance and calculates the best method to control CO

2

 within the area. 

It then uses this information in conjunction with a simple form of Artificial Intelligence called Fuzzy-logic to give you truly exceptional 
efficiency.  Auto-tuning is only required when using compressed CO

2

 and Fuzzy-logic control mode.

There are ONLY four reasons to perform “Auto-Tuning” and most people will not see any improvement over the factory setpoints. 

1)  Unsatisfactory performance after operating the unit for a few days.

2)  Changing the set point (SV) more than 500 PPM.

3)  Major (and some minor) changes in the CO

2

 delivery system, area configuration, fan changes, ECT.

4)  Abnormal or inconsistent results from previous Auto-Tunings. 

*Note: NEVER perform an Auto-tune when using a CO

2

 generator.

Summary of Contents for XGC-1e

Page 1: ...e maximum rating of the XGC 1e IMPORTANT Replace blown fuses with fuses of the same rating ONLY Note A surge suppressor power strip is always recommended when operating electrical equipment such as th...

Page 2: ...the best all in one controller available Humidity Controller Temperature Controller 2 Light Outlets 2 Hydro pump Outlets Hydro OFF timer Hydro mode selector switch Fuzzy Logic CO2 controller Fuse pro...

Page 3: ...ion of this manual Set the Hydro ON and OFF timers to your desired settings before continuing Refer to Timers 8 The 24 hour timeclock can now be set Push in the trip levers on the front face of the ti...

Page 4: ...levels The de humistat can control humidity levels from 20 80 The de humistat is coordinated with the CO2 control system and the exhaust receptacles to maintain a constant humidity When the humidity r...

Page 5: ...during the daytime only Simply moving the Hydro Mode selector switch to either the 24 Hour or the Daytime position enables the desired mode When used in the Daytime mode the Hydro outlet will only cyc...

Page 6: ...ssible However if you suspect the higher temperatures are adversely affecting the plants a shorter CO2 cycle may produce better results Remember that a shorter CO2 cycle duration translates to increas...

Page 7: ...is complete 14 Reconnect the Exhaust fans CO2 Disable cable and return the area to normal operation while monitoring the level of CO2 Do not continue to stand next to the XGC 1e while monitoring Just...

Page 8: ...XGC 1e is capable of remaining in calibration for a minimum of three years Extreme shock during shipping and other factors may affect the calibration To check the calibration follow the procedure bel...

Page 9: ...the HPR 1 The HPR 1 is rated at 30 amps 120 240 volt Master Lighting Controller Mlcs The MLC 4X and MLC 4XT Master Lighting Controllers are the best devices for controlling up to 4 HID lights from one...

Page 10: ...circuits If the fuse blows repeatedly verify the devices connected to the unit are working properly and that they are not too large for the XGC 1e to safely control You may need to consider using exp...

Page 11: ...00 PPM CO2 CO2 Warm up time Minimum 10 minutes full accuracy CO2 Maximum drift per year 15 PPM CO2 Accuracy 77 F 5 of reading CO2 Repeatability 1 of Fixed Scale CO2 Calibration interval Three years CO...