1)  Please take care in the handling of this precision device. If the unit is dropped or subjected to extreme shock, the calibration  
 

may  be thrown off. Calibration problems due to abuse, or droppage may affect the warranty. 

2)  DO NOT expose the XGC-1e to water. It utilizes a ventilated enclosure to properly “sample” the CO

2

.

s

pecificaTions

:

System operating voltage 

/- 20% @ 50-60 Hertz

Maximum Switching amperage 

15-amps @ 120vac

Overload protection 

15-amp normal blow fuse

Operating temperature  

30-120º F

Maximum humidity  

95% RH (Non-condensing)

Temperature control range 

50-115º F with a 7º F differential, +/- 3.6º

Humidity control range 

20 - 80% RH with a 5% differential

Adjustable timer repeatability 

+/- .5% under fixed conditions

Timer setting accuracy 

+/- 10% 

Hydro “ON” timer 

30 seconds to 20 minutes

Hydro “OFF” timer 

12 minutes to 480 minutes

24-hour timeclock accuracy 

+/- 3% monthly

CO

2

 Operating principle 

Fuzzy Logic™, w / Single-beam Non-Dispersive Infrared (NDIR)

CO

2

 Measurement range 

0 – 5000 PPM CO

2

CO

2

 Warm-up time 

Minimum 10 minutes (full accuracy)

CO

2

 Maximum drift per year 

+/- 15 PPM

CO

2

 Accuracy @ 77’F 

+/- 5% of reading

CO

2

 Repeatability 

< 1% of Fixed Scale

CO

2

 Calibration interval 

Three years

CO

2

 sensor Operating life expectancy 

15 years typical

Dimensions 

10” X 8” X 7”

Weight 

Less than 6 lbs.

Relay operations 

Minimum 100,000 electrical / 10,000,000 mechanical

m

ainTenance

:

 1)  Consult the troubleshooting chart for a listing of the most common problems.

2)  DO NOT open the enclosure!!! There are no components that require maintenance.

3)   Do not use this equipment for purposes other than what it is designed for. It will provide many years of trouble-free service when 

used properly.

4)   In the event you cannot solve the problem, first consult the dealer who sold the unit then contact the factory for instructions on 

how to return it to the factory for repair.

Published By R & M Supply Inc.

Copyright 2009 R & M Supply

All Rights Reserved.

Liability statement:

R & M Supply and their retailers and distributors are not responsible for any damage or injuries (consequential or otherwise) arising 
from the use of this device. The purchaser assumes all responsibility for the use and proper installation of this device.

Summary of Contents for XGC-1e

Page 1: ...e maximum rating of the XGC 1e IMPORTANT Replace blown fuses with fuses of the same rating ONLY Note A surge suppressor power strip is always recommended when operating electrical equipment such as th...

Page 2: ...the best all in one controller available Humidity Controller Temperature Controller 2 Light Outlets 2 Hydro pump Outlets Hydro OFF timer Hydro mode selector switch Fuzzy Logic CO2 controller Fuse pro...

Page 3: ...ion of this manual Set the Hydro ON and OFF timers to your desired settings before continuing Refer to Timers 8 The 24 hour timeclock can now be set Push in the trip levers on the front face of the ti...

Page 4: ...levels The de humistat can control humidity levels from 20 80 The de humistat is coordinated with the CO2 control system and the exhaust receptacles to maintain a constant humidity When the humidity r...

Page 5: ...during the daytime only Simply moving the Hydro Mode selector switch to either the 24 Hour or the Daytime position enables the desired mode When used in the Daytime mode the Hydro outlet will only cyc...

Page 6: ...ssible However if you suspect the higher temperatures are adversely affecting the plants a shorter CO2 cycle may produce better results Remember that a shorter CO2 cycle duration translates to increas...

Page 7: ...is complete 14 Reconnect the Exhaust fans CO2 Disable cable and return the area to normal operation while monitoring the level of CO2 Do not continue to stand next to the XGC 1e while monitoring Just...

Page 8: ...XGC 1e is capable of remaining in calibration for a minimum of three years Extreme shock during shipping and other factors may affect the calibration To check the calibration follow the procedure bel...

Page 9: ...the HPR 1 The HPR 1 is rated at 30 amps 120 240 volt Master Lighting Controller Mlcs The MLC 4X and MLC 4XT Master Lighting Controllers are the best devices for controlling up to 4 HID lights from one...

Page 10: ...circuits If the fuse blows repeatedly verify the devices connected to the unit are working properly and that they are not too large for the XGC 1e to safely control You may need to consider using exp...

Page 11: ...00 PPM CO2 CO2 Warm up time Minimum 10 minutes full accuracy CO2 Maximum drift per year 15 PPM CO2 Accuracy 77 F 5 of reading CO2 Repeatability 1 of Fixed Scale CO2 Calibration interval Three years CO...

Reviews: