C.A.P. XGC-1e Specification Sheet Download Page 4

“c

ontrolS

o

vervieW

 

 “The XGC-1e controls your lights, hydroponic pumps, exhaust fan or A/C, de-humidifier, heater and CO2 level with “Part-Per-Million” 
accuracy… automatically! No more guesswork! 

24 h

our

 T

imeclock

The timeclock selected to run the XGC performs all of the day to night transitions required for crops requiring controlled photoperiods. It 
can directly control up to 1000 watts of HID lights. 

 To set the current time on the timeclock, turn the dial clockwise until the current time on the outer dial lines up with the arrow on the 
inner dial. To set the timeclock on and off times, carefully push in each of the orange trip levers at the times you want the lights to be on.

*NOTE: If power is interrupted, the timeclock will have to be reset.

T

emperaTure

 c

onTroller

The  XGC  utilizes  a  remote-bulb  thermostat  with  a  30”  lead  to  control  ventilation  and  cooling  functions.  This  allows  you  to  place  the 
temperature sensor up to 30” away from the XGC. The thermostat can be set to control temperature from 50 – 115’F. 

The thermostat is coordinated with the CO

2

 control system and the exhaust receptacles to maintain a constant temperature. When the 

temperature rises above the set point selected on the thermostat, the CO

2

 system is disabled and the Exhaust receptacles are enabled. 

When the temperature level drops below the set point, the CO

2

 system is re-activated. 

IMPORTANT: To achieve the greatest accuracy, provide the XGC with plenty of “fresh air”. The enclosure is designed to allow air to 
pass over the humidity sensor

h

umidiTy

 c

onTroller

The XGC utilizes a de-humistat to control ventilation and humidity levels. The de-humistat can control humidity levels from 20% - 80%.  

The  de-humistat  is  coordinated  with  the  CO

2

  control  system  and  the  exhaust  receptacles  to  maintain  a  constant  humidity.  When  the 

humidity rises above the set point selected on the de-humistat, the CO

2

 system is disabled and the Exhaust receptacles are enabled. When 

the humidity level drops below the set point, the CO

2

 system is re-activated. 

h

ydro

 m

ode

 s

elecT

 s

WiTch

The Hydro mode select switch is used to select whether the hydro outlet will cycle 24-hours or only during the day. The mode selector 
switch also doubles as a Hydro bypass switch. Each time the switch position is changed to the center “OFF” position, the hydro timers 
will reset and initiate a new cycle. This comes in handy during set-up of the hydro pumps and timer settings. 

NOTE: *Leaving the mode select switch in the center position disables the hydro function.

n

iGhT

 o

nly

 d

evice

An  additional  outlet  is  provided  which  is  powered  only  at  “night”  when  the  lights  are  turned  OFF.  This  works  great  for  heaters,  fans, 
dehumidifiers or any other device that needs to run only at night.    

W

haT

 i

s

 “f

uzzy

 l

oGic

  c

o

2

 c

onTrol

?

What set’s the XGC-1e apart from the competition? Fuzzy logic… What is “fuzzy logic”? Fuzzy Logic can be compared to a good driver. 
As a good driver approaches a red light, he or she applies the brakes to gradually slow down BEFORE getting to the intersection. Fuzzy 
Logic uses the same idea to bring the CO

2

  level up to the desired setting without going over the set point. With Fuzzy Logic, relatively safe 

compressed CO2  can replace LP / gas CO

2

  generators economically.

 The XGC combines an extremely accurate infrared CO

2

 sensor with a state-of –the-art Fuzzy Logic module to give you the most precise 

method of controlling supplemental CO2.   

SIMPLY SET IT… AND FORGET IT!

Summary of Contents for XGC-1e

Page 1: ...e maximum rating of the XGC 1e IMPORTANT Replace blown fuses with fuses of the same rating ONLY Note A surge suppressor power strip is always recommended when operating electrical equipment such as th...

Page 2: ...the best all in one controller available Humidity Controller Temperature Controller 2 Light Outlets 2 Hydro pump Outlets Hydro OFF timer Hydro mode selector switch Fuzzy Logic CO2 controller Fuse pro...

Page 3: ...ion of this manual Set the Hydro ON and OFF timers to your desired settings before continuing Refer to Timers 8 The 24 hour timeclock can now be set Push in the trip levers on the front face of the ti...

Page 4: ...levels The de humistat can control humidity levels from 20 80 The de humistat is coordinated with the CO2 control system and the exhaust receptacles to maintain a constant humidity When the humidity r...

Page 5: ...during the daytime only Simply moving the Hydro Mode selector switch to either the 24 Hour or the Daytime position enables the desired mode When used in the Daytime mode the Hydro outlet will only cyc...

Page 6: ...ssible However if you suspect the higher temperatures are adversely affecting the plants a shorter CO2 cycle may produce better results Remember that a shorter CO2 cycle duration translates to increas...

Page 7: ...is complete 14 Reconnect the Exhaust fans CO2 Disable cable and return the area to normal operation while monitoring the level of CO2 Do not continue to stand next to the XGC 1e while monitoring Just...

Page 8: ...XGC 1e is capable of remaining in calibration for a minimum of three years Extreme shock during shipping and other factors may affect the calibration To check the calibration follow the procedure bel...

Page 9: ...the HPR 1 The HPR 1 is rated at 30 amps 120 240 volt Master Lighting Controller Mlcs The MLC 4X and MLC 4XT Master Lighting Controllers are the best devices for controlling up to 4 HID lights from one...

Page 10: ...circuits If the fuse blows repeatedly verify the devices connected to the unit are working properly and that they are not too large for the XGC 1e to safely control You may need to consider using exp...

Page 11: ...00 PPM CO2 CO2 Warm up time Minimum 10 minutes full accuracy CO2 Maximum drift per year 15 PPM CO2 Accuracy 77 F 5 of reading CO2 Repeatability 1 of Fixed Scale CO2 Calibration interval Three years CO...