XGC-1e

 Xtreme Greenhouse Controller

The  XGC-1e  Xtreme  greenhouse  controller  from  C.A.P.  controls  all  of  the 
main devices that are used in today’s modern hydroponic garden. The built-in 
Fuzzy Logic

  controls your CO

2

 level with unmatched accuracy.

W

ord

 T

o

 T

he

 W

ise

...

Before attempting to operate the XGC, you should at least take the time to 
look  at  the  Example  Connection  diagram  on  page  2  and  read  the  “Start-
up  Procedure  on  page  3  of  this  manual.  To  get  the  most  out  of  the  XGC-
1e,  familiarize  yourself  with  this  manual.  It  contains  many  useful  hints, 
examples and a troubleshooting guide.

i

mporTanT

 s

Tuff

 T

o

 r

emember

 The XGC is designed to operate from a 120vac, 15-amp power source.  It can 
safely control up to 15-amps of equipment including up to 1000 watts of HID 
lights. If required, additional lights and larger equipment can be connected 
to the XGC-1e by using our HPR, MLCs or UPM “Universal Power Modules”. 

In addition to lights, the XGC also maintains the temperature and humidity by 
controlling your exhaust fan(s). CO

2

 levels can be controlled with the built-

in timers, which are coordinated with your exhaust fans and function only 
when the lights are ON. 

p

roTecTion

 & s

afeTy

The  XGC  is  overload  protected  a  main  15-amp  fuse.  Do  not  exceed  the 
maximum rating of the XGC-1e.

IMPORTANT

: Replace blown fuses with fuses of the same rating ONLY! 

Note:  A  surge  suppressor  /  power  strip  is  always  recommended  when 
operating electrical equipment such as the XGC. 

W

arranTy

 

The  XGC  is  protected  by  our  3-year  limited  warranty.  All  components  are 
warranted by R & M Supply against defects in workmanship and materials under normal use for 3-years from the date of purchase. The XGC 
is 100% maintenance-free and does not require service. 

i

nsTallaTion

 / s

TarT

-u

p

There are a few requirements for a successful installation and start-up.

1)

 The XGC must be mounted in a vertical position. Mounting feet are included to allow you to secure the unit to a wall. 

2)

 The XGC requires “free air movement” to maintain temperature and humidity accuracy. The top and bottom of the enclosure has  

 

  ventilation slots to provide airflow through the unit however, we greatly recommended using an oscillating fan in the growing area to  
  provide fresh air for the internal humidity sensor and provide adequate ventilation for the internal electrical components. 

3)

 A dedicated 120 VAC, 15-amp power supply is recommended. A ground wire (3-wire outlet) must be used.  Do not use 2-wire adapters or  

  cords to operate the XGC. 

4)

 The XGC must be protected from water. Do not mount the unit where it can be exposed directly to water.

5)

  Read the rest of the manual!!! It has been designed to take you through step-by-step to make start-up a breeze. 

Summary of Contents for XGC-1e

Page 1: ...e maximum rating of the XGC 1e IMPORTANT Replace blown fuses with fuses of the same rating ONLY Note A surge suppressor power strip is always recommended when operating electrical equipment such as th...

Page 2: ...the best all in one controller available Humidity Controller Temperature Controller 2 Light Outlets 2 Hydro pump Outlets Hydro OFF timer Hydro mode selector switch Fuzzy Logic CO2 controller Fuse pro...

Page 3: ...ion of this manual Set the Hydro ON and OFF timers to your desired settings before continuing Refer to Timers 8 The 24 hour timeclock can now be set Push in the trip levers on the front face of the ti...

Page 4: ...levels The de humistat can control humidity levels from 20 80 The de humistat is coordinated with the CO2 control system and the exhaust receptacles to maintain a constant humidity When the humidity r...

Page 5: ...during the daytime only Simply moving the Hydro Mode selector switch to either the 24 Hour or the Daytime position enables the desired mode When used in the Daytime mode the Hydro outlet will only cyc...

Page 6: ...ssible However if you suspect the higher temperatures are adversely affecting the plants a shorter CO2 cycle may produce better results Remember that a shorter CO2 cycle duration translates to increas...

Page 7: ...is complete 14 Reconnect the Exhaust fans CO2 Disable cable and return the area to normal operation while monitoring the level of CO2 Do not continue to stand next to the XGC 1e while monitoring Just...

Page 8: ...XGC 1e is capable of remaining in calibration for a minimum of three years Extreme shock during shipping and other factors may affect the calibration To check the calibration follow the procedure bel...

Page 9: ...the HPR 1 The HPR 1 is rated at 30 amps 120 240 volt Master Lighting Controller Mlcs The MLC 4X and MLC 4XT Master Lighting Controllers are the best devices for controlling up to 4 HID lights from one...

Page 10: ...circuits If the fuse blows repeatedly verify the devices connected to the unit are working properly and that they are not too large for the XGC 1e to safely control You may need to consider using exp...

Page 11: ...00 PPM CO2 CO2 Warm up time Minimum 10 minutes full accuracy CO2 Maximum drift per year 15 PPM CO2 Accuracy 77 F 5 of reading CO2 Repeatability 1 of Fixed Scale CO2 Calibration interval Three years CO...

Reviews: