background image

BZBGEAR BZ-MVS8x8-4K

PRODUCT MANUAL

Back Panel

Control interfaces: LAN (10M/100M), RS232-1/RS232-2, IR

Analog Audio IN/OUT ports are bonded with corresponding HDMI ports.

For example, if INPUT HDMI 1 signal is DVI, matrix will use analog AUDIO IN 1 as

HDMI 1 audio source

Note

: Analog AUDIO IN is only available when the corresponding video input is a

DVI signal.

Analog AUDIO OUT will always output the same audio content as the corresponding

HDMI OUTPUT and Analog Audio IN connection.

IR IN and IR OUT

IR IN/OUT is for remote control routing and follows the video routing, for example, if
HDMI 1 INPUT is routed to HDMI 1 and 2 OUTPUT ports, then IR IN 1 and 2 will be

routed to IR OUT . Please refer to the illustration below.

Address:

830 National Drive #140, Sacramento, CA 95834, USA

·

Tel:

+1(888)499-9906

·

Email:

[email protected]

8

Summary of Contents for BZ-MVS8x8-4K

Page 1: ...BZ MVS8x8 4K 8X8 4K UHD 18Gbps HDMI Video Wall Processor Seamless Matrix Switcher with Scaler IR and Audio User Manual...

Page 2: ...BZBGEAR BZ MVS8x8 4K PRODUCT MANUAL Address 830 National Drive 140 Sacramento CA 95834 USA Tel 1 888 499 9906 Email support bzbgear com 2...

Page 3: ...trol 9 UART Control 11 Network Control 12 Connection via LAN 14 Configure the Network of the Device via UART 14 Configure the Network of the Device via LAN 15 Matrix Switch 16 Signal Setting 17 EDID C...

Page 4: ...icrofiber cloth To prevent the risk of electric shock do not open the case Installation and maintenance should only be carried out by qualified technicians Do not use the product beyond the specified...

Page 5: ...so available on this unit via IR extenders through the 8 IR inputs and outputs Features HDMI 2 0 HDCP 2 2 Seamless switching IR matrix HDMI audio extraction External L R audio embedding to HDMI stream...

Page 6: ...0x1080 60Hz 3840x2160 30Hz 3840x2160 60Hz 1280x720 60Hz 1024x768 60Hz 1360x768 60Hz 1600x1200 60Hz 1920x1200 60Hz HDMI Amplitude T M D S 0 4Vpp Differential impedance 100 15ohm RS232 Ethernet control...

Page 7: ...ons in sequence to save the current matrix routing as a scene The maximum allowable number of scenes is 8 Press the RECALL OUTPUT buttons in sequence to recall a saved scene to be used as the current...

Page 8: ...the corresponding video input is a DVI signal Analog AUDIO OUT will always output the same audio content as the corresponding HDMI OUTPUT and Analog Audio IN connection IR IN and IR OUT IR IN OUT is f...

Page 9: ...ctor RS 232 control baud rate 9600 DB9 connector Pins configuration as below User need use the corresponding cable directly link cable Index Pin 1 N u 2 Tx Matrix PC 3 Rx Matrix PC 4 N u 5 Gnd 6 N u 7...

Page 10: ...MVS8x8 4K PRODUCT MANUAL Baud rate 9600 Ethernet control and connection Note Factory default network setting Address 830 National Drive 140 Sacramento CA 95834 USA Tel 1 888 499 9906 Email support bzb...

Page 11: ...he PC control tool and select the Matrix Switch page 3 Click the radial in the Ctrl Mode section for UART 4 Click the Port drop down box and select the currently used COM port for the device 5 Click t...

Page 12: ...on via Ethernet cable 1 Connect the PC and device directly via an Ethernet cable 2 Change the IP address of the PC to be in the same subnet of the device a Default IP Address 192 168 0 247 b Default S...

Page 13: ...lick the Search Device button at the bottom 6 Click the device you want to control in the result list When you click it the software will read the network configuration 7 Click the Disconnected button...

Page 14: ...d button to connect to the device 8 If connected successfully the Status button will show Connected Configure the Network of the Device via UART 1 Connect to the device using a serial cable and config...

Page 15: ...Search Device button to search and load the configuration to ensure your modifications saved successfully NOTE 1 Configuration via Network connection allows users to edit the device s name to better...

Page 16: ...and Output names by clicking the text fields 2 To save a scene select a mode from the SaveAs dropdown Mode1 Mode8 3 To recall a scene select a mode from the Recall dropdown Mode1 Mode8 4 To set one in...

Page 17: ...ut port then click the Read button to read EDID settings 2 Write EDID First read an EDID from an output port or open an EDID file that was saved before select the input port and click the Write button...

Page 18: ...rol interface 4 If the IP address of the matrix is known type in the IP address in your web browser 5 Enter the Username admin and Password admin to login and control the device NOTE The computers IP...

Page 19: ...lp setting up configuring and other helpful how to videos about our gear Need more in depth support Connect with one of our technical specialists directly Phone 1 888 499 9906 Email support bzbgear co...

Page 20: ...ur catalog BZBGEAR delivers quality products designed with users in mind Copyright All the contents in this manual and its copyright are owned by BZBGEAR No one is allowed to imitate copy or translate...

Reviews: