from being exposed to moisture or sunlight, like using connector
endcaps.
DANGER:
One single module may generate more than 30V DC
when its front is exposed to direct sunlight. If modules are
connected in series, the total voltage is equal to the sum of the
partial voltages of each module .A nominal open voltage or maximum system
voltage of 45 V or more may cause an electric shock, exist in the conspicuous
position of a module connection part. Therefore direct contact should be
avoided after installing a greater number of modules in series or parallel, in
order to avoid electric shocks.
CAUTION:
Please unpack the module in an appropriate
environment, and use special tools. The modules need to be
kept water-proof and damp-proof.
NOTE:
BYD does not limit the materials of the installation as long as they can
be used outdoors for at least 25 years
3.2 Mechanical installation
3.2.1 Mounting system
Use screws put through the mounting holes according to the following
figure for fixing the module,If all mounting holes are used,
2400 Pa wind
load and 5400 Pa snow
(IEC61215 2005); a load of 3600Pa for frontal, a
load of 1600Pa for back(IEC61215 2016 safety factor 1.5).
Description of the mounting holes:
FIG.2 P6K series models