BYD COMPANY LIMITED
Document
Installation Manual and User Manual for BYD
Project No.
\
Code
2M SOP0007540
Edition
13
Page
12 / 22
12
Model
Measure
A
Measure
B
BYDxxxP6K-18
120
250
BYDxxxM6K-18
BYDxxxP6K-24
110
250
BYDxxxP6K-27
120
250
BYDxxxP6C/K-30(L=1640)
140
250
BYDxxxM6C/K-30(L=1640)
BYDxxxP6C/K-30(L=1650)
145
250
BYDxxxM6C/K-30(L=1645)
142.5
250
BYDxxxP6C/K-30(L=1645)
BYDxxxPHC/K-30 (L=1669)
158
250
BYDxxxMHC/K-30 (L=1669)
BYDxxxPHC/K-30(L=1658)
149
250
BYDxxxMHC/K-30(L=1658)
BYDxxxPIC/K-30(1684)
162
250
BYDxxxMIC/K-30(1684)
162
250
BYDxxxP6C/K-36(L=1956)
328
250
BYDxxxM6C/K-36(L=1956)
BYDxxxP6C/K-36(L=1962)
331
250
BYDxxxM6C/K-36(L=1962)
BYDxxxPHC/K-36(L=1992)
346
250
BYDxxxMHC/K-36(L=1992)
BYDxxxPHC/K-36(L=1978)
339
250
BYDxxxMHC/K-36(L=1978)
BYDxxxPIC/K-36(2008)
354
250
BYDxxxMIC/K-36(2008)
354
250
BYDxxxPIC/K-39(L=2166)
433
250
BYDxxxMIC/K-39(L=2166)
433
250
Remark:
“A” denotes the distance from the clamp to the edge of the module,
while
“B” denotes the possible clamping range.
Installation method:
FIG. 7 Schematic diagram of long side pressing block
We advise users to use an installation method as shown in the two
pictures above, as this method renders modules connection rather fast.
Installation method with clamping on the short side of the frame as
below: