13
FIG. 8 Schematic diagram of four clamps under pressure of
2400Pa
(IEC61215 2005 )
Installation method:
FIG. 9 Schematic diagram of short side pressing block
(IEC61215 2005)
Notice:
If customer choose Installation method with clamping on
the short side of the frame, you should customize the length of
the electric cable for us.
3.2.3 Insertion system
For the modules to follow an insertion system as depicted below
can be used for installation. T
he insertion system must have enough
strength to fix modules, and can be made of materials such as stainless
steel and other appropriate metals for solid support of the PV modules.
FIG. 10 Installation diagram of long side guide rail under pressure
of 2400Pa(IEC61215 2005 )
FIG. 11 Guide rail installation diagram
During the installation on the long side of the frame you need to
take care that the cells on the front side and that the grounding holes on
the back side don´t get covered. Please refer to the detailed illustration