49
1
POWER
keep on
2
LOCAL
keep on
On-grid forced charge
Close the MINI ES circuit breaker for the AC grid to supply power to the MINI ES.
Hold "REMOTE" and "LOCAL" button at the same time for 10s. Then "REMOTE",
"LOCAL" indicators all keep on, the system will start forced charging mode.
While charging, let MINI ES operate for more than 15mins before using APP to search
system data; if App works normally and displayed data correspond to the actual
situation, trial test is completed. Complete the check list.
Record results as follows:
Forced charge data
No.
Contents
Requirements
Results
1
APP main interface
displays grid power data.
Cannot be
“0” if
grid is presented
2
APP main interface
displays photovoltaic
power data.
Cannot be
“0”; if
inverter is
generating power
If APP data is correct, hold
“REMOTE” and “LOCAL” button for 5s, “REMOTE”
、
“LOCAL” and “POWER” indicators are all off, forced charge mode is finished.
Long hold
“POWER” button for 10s, “POWER” indicator will be off, and the system will
be turned off.
4.11 Finishing off
Before starting recovery the system, firstly disconnect MINI ES grid power and turn off the
system.
DANGER!
·
Before installing sideboard, please make sure energy storage system has
already been turned off And denergised.