39
No.
Item
Remark
⑨
LOAD
Load inlet port
⑩
PV INVENTER
Reserved (Prohibition of use)
The internal connection
Please wire according to the interface instructions below.
Related tools: a small screwdriver, side cutters, stripping pliers, wire crimpers,
Cable connection of grid
Connect a circuit breaker (with Max. Current limit of 25A) between main switch board
(grid) and MINI ES
Cable connection of load
Connect a circuit breaker (with Max. Current limit of 25A) between essential load and
distribution board.
Communication Cable connection of grid current transducer
Communication Cable connection of PV current transducer
Network line connection
CAUTION!
Leakage protection
According to different countries and areas standard requirements, please choose
appropriate current leakage protection breaker device. The MINI ES shall has good
grounding.
NOTICE!
·
The glands need to be loosed.
·
All cables need to penetrate the gland of cable first, then penetrate the holes,
finally connect the cable to the internal interface.
·
Tighten the glands around the cable after completing the internal connections.