![Byan 600A Series Installation And Operator'S Manual Download Page 19](http://html.mh-extra.com/html/byan/600a-series/600a-series_installation-and-operators-manual_2836899019.webp)
-19-
MODEL 600 SERIES OPERATOR | Rev. 2019.7.1
600 RESIDENTIAL OPERATOR
Mounting Dimensions
(These dimensions are calculated using a 4-inch gate post, a 2-inch gate leaf, and a 1.75-inch distance from
the face of the gate post to the center of the gate hinge. Your dimensions may be slightly different, so please
contact Byan Systems for help in getting the proper mounting dimensions for your gate.)
Inward Swing
DEGREE OF ANGLE
A DIMENSION
B DIMENSION
C DIMENSION
75
6-
3/4”
4-
1/4”
2-
3/4”
80
6-
1/4”
4-
1/4”
2-
3/4”
85
5-
7/8”
4-
1/4”
2-
3/4”
90
5-
1/4”
4-
1/2”
2-
3/4”
Outward Swing
DEGREE OF ANGLE
A DIMENSION
B DIMENSION
C DIMENSION
75
6-
3/4”
4-
1/4”
2-
3/4”
80
6-
1/4”
4-
1/4”
2-
3/4”
85
5-
5/8”
5”
2-
3/4”
90
4-
7/8”
5”
2-
3/4”
(These dimensions are calculated using a 6-inch gate post, a 2-inch gate leaf, and a 1.75-inch distance from
the face of the gate post to the center of the gate hinge. Your dimensions may be slightly different, so please
contact Byan Systems for help in getting the proper mounting dimensions for your gate.)
Inward Swing
DEGREE OF ANGLE
A DIMENSION
B DIMENSION
C DIMENSION
75
6-
3/4”
4-
1/4”
3”
80
6-
1/4”
4-
1/4”
3”
85
5-
7/8”
4-
1/4”
2-
3/4”
90
5-
3/8”
4-
3/8”
2-
3/4”
Outward Swing
DEGREE OF ANGLE
A DIMENSION
B DIMENSION
C DIMENSION
75
6-
1/2”
4-
1/2”
3”
80
6-
1/8”
4-
1/2”
3”
85
5-
5/8”
4-
1/2”
2-
3/4”
90
4-
7/8”
5”
2-
3/4”
NOTE:
The minimum distance from the rear post face to the rear mounting bracket is 1-
3/4”.
(
Please contact Byan Systems with your gate measurements for anything less than 75 degrees and more than 90
degrees.)