-14-
MODEL 600 SERIES OPERATOR | Rev. 2019.7.1
PRESSURE AND FLOW CONTROL
When mounting the operator to your gate,
always
make sure that the side with the lock cap (or
the Green and Red Pressure Adjustment Screws) is facing upward. Mounting your operator in
an upside-down position will result in it failing to run properly.
⧫
Pressure and flow control
are factory set for best
performance.
⧫
If pressure adjustment in
required, the Extend and
Retract pressures must be
adjusted
equally
. Equal
adjustment to controls is
required to increase and
decrease pressure.
⧫
Flow control is set by the
factory for maximum speed.
⧫
To reduce the operator’s
speed, turn the flow control
screw clockwise up to one-
half turn.
⧫
DO NOT TURN THE FLOW
CONTROL ADJUSTMENT
SCREW COUNTER-
CLOCKWISE FROM THE
FACTORY SETTING.
⧫
The manual by-pass
screw is set at the factory
and can be released with
the allen wrench provided.
Do not turn more than one
turn counter-clockwise to
move the gate manually.