background image

 

 

EN

 

14  

9.4

 

Start-up test 

 

 

 

 

 

 

 

 

Name of customer:

Plant number:

Work-sheet number:

Type of plant:

Permeate flow  [l/h]:

Concentrate flow  [l/h]:

In case of problems, please fill in the problem report

Can the problem be related to the manufacturing?

Can the problem be related to the plant or the installation?

The plant - we mean only the part of the whole installation which was delivered by BWT (i.e only the plant).
The installation - we mean the piping etc. leading to the plant.

Can the problem be related to the sales department?

Description, please describe the problem

Signature

Name/initials of technician:

Date:

Time consumption for the start-up [hours]:

Problem report

The start-up test sheet must be completed and filed together with the operating journal.

RO plant

BWT PERMAQ Compact CRU 

Status on start-up

Problems on start-up

Pressure switch start/stop, transport pump is OK

Drainage protection, overflow branch is connected to the drain 

Pre-pressured hydrophore is OK

YES, there were problems at start-up

Start-up by dealer, specify dealer _____________________________________

YES, the  problem can be related to the manufacturing

NO, the problem cannot be related to the manufacturing

NO, there were no problems at start-up

Start-up by BWT 

YES, the problem only concerns the plant

YES, the problem only concerns the installation

YES, the problem concerns both the plant and the installation

NO, the problem does not concerns the plant or the installation

YES, the customer was misinformed

NO, the customer had been well-informed

Max. concentrate flow from RO to the CRU is < 500 [l/h]

Summary of Contents for CRU 200

Page 1: ...BW T CRU 38 200 600 Concentrate Reusable Unit Installation and Operating manual EN...

Page 2: ...Technical specifications and settings 5 7 Survey of alarm conditions settings 6 7 1 Trouble shooting 7 8 Technical specifications 9 9 Annex 10 9 1 El diagram 10 9 2 PI diagram 12 9 3 Arrangement draw...

Page 3: ...Is a switch which gives a signal when the RO plant must either be started or stopped and it stops the transport pump in case of dry running of the tank 3 Functional description The BWT CRU is a unit...

Page 4: ...ain 1 hose Important If the water connection for consumption is too small there is a risk of outage on the unit due to lacking water pressure amount In general pressure losses should be mini mized Imp...

Page 5: ...not touch the level switch Create a large consumption of water for 5 min the TP pump needs to be bled of air Check that the transport pump starts automatically Check that the pump supplies water and...

Page 6: ...low water level no ALARM TP pump stopped See Fault 1 External stop TP pump can be jumped at start up Remove the cause for external stop signal CRU unit is running everything OK CRU unit is on Standby...

Page 7: ...if the level switch and or the level switch cable are defective If so replace Check the TP pump See Fault 1 Fault 2 and Fault 3 Fault 2 TP pump doesn t run Switch is at OFF Push switch to ON Low water...

Page 8: ...start automatically Fault 4 TP pump starts and stops If the piping connection is too small there is a risk of outages on the plant due to lacking water pressure amount etc Replace the outlet pipe wate...

Page 9: ...h 3 bar 3 m3 h 3 bar 3 m3 h Height Width Depth 810 580 630 mm 810 580 630 mm 810 580 630 mm Concentrate inlet diameter 12 mm 12 mm 12 mm Consumption water outlet diameter 3 4 3 4 3 4 Raw water inlet d...

Page 10: ...EN 10 9 Annex 9 1 El diagram...

Page 11: ...EN 11...

Page 12: ...EN 12 9 2 PI diagram...

Page 13: ...EN 13 9 3 Arrangement drawing 9 3 1 Arrangement drawing BWT CRU 38 200 600...

Page 14: ...completed and filed together with the operating journal RO plant BWT PERMAQ Compact CRU Status on start up Problems on start up Pressure switch start stop transport pump is OK Drainage protection ove...

Page 15: ...EN 15 9 5 Spare parts drawings 9 5 1 Spare parts drawing BWT CRU 38 200 600...

Page 16: ...3 Hose 400 mm 451404189 4 Push in fitting 12x12 Elbow 454090012 3 year 5 Non return valve 200729004 6 Magnetic valve housing 200753004 7 Wheels 403899070 8 Level Switch 451404430 9 Hydrophore 0 5 lit...

Page 17: ...y local public disposal operations not even by small commercial operators For disposal in Denmark and in the other member nations of the European Economic Area EEA please contact our local BWT service...

Page 18: ...45 43 600 900 bwt bwt dk www bwt dk Herewith declares that BWT CRU 38 200 600 is in conformity with the provisions of the Machinery Directive directive 2006 42 EC is in conformity with the provisions...

Page 19: ...s Cedex Tel 33 1 4922 45 00 Fax 33 1 4922 45 45 E Mail bwt bwt fr BWT Belgium NM Leuvensesteenweg 633 B 1930 Zaventem Tel 32 2 758 03 10 Fax 32 2 758 03 33 E Mail bwt bwt be BWE esk Republika s r o Li...

Reviews: