AUTOMATIC DISPLAYED MESSAGES
The displays shows:
an upper information line
a lower information line
a bargraph with 10 segments, showing the
remaining autonomy of the softener before the
next regeneration, by steps of 10%. The graph
in this example shows 70% remaining autonomy
For each operation step of the device, the dis-
played messages are as follows:
ADVANCED SETTING
Accessed by the code
23
, then the browsing works in the same way as the regular setting mode. The intervention on the advanced setting shall be
done by a trained professional. Any mistake can disturb the work of the device and is under its author’s responsibility.
Step n°
Display
Purpose
Action
0
PASSW ?
00
Enter the password to go through the advanced setting.
êé
to change
OK
to confirm
ç
M
to cancel
1
PROP R
On
Enable / disable the proportional regeneration.
ê
to turn on / off
OK
to confirm
ç
M
to cancel
2
CAPA
80
Modify the softening capacity of the device, which has been automati-
cally set once the resin volume was selected (step 3 of regular setting).
êé
to change
OK
to confirm
ç
M
to cancel
3
CONSU
71
Adjust the water consumption per full regeneration.
Only for devices with the salt level follow-up by smartphone app.
êé
to change
OK
to confirm
ç
M
to cancel
4
SALT
2000
Adjust the salt consumption per full regeneration.
Only for devices with the salt level follow-up by smartphone app.
êé
to change
OK
to confirm
ç
M
to cancel
5
VOL OK
8 56
Volume of softened water (read only info). Here: 856 liters.
ç
M
to go to next step
6
PEAKFL
10 68
Peak flow recorded since the last regeneration (read only info). Here:
1068 liters per hour.
ç
M
to go to next step
7
N REGE
48
Number of regenerations done since the commissioning. May be reset.
êé
to change
OK
to confirm
ç
M
to cancel
8
CHLOR
Off
Enable / disable the chlorination function
êé
to change
OK
to confirm
ç
M
to cancel
9
ALARME
Off
Salt lack alarm enabled / disabled
êé
to change
OK
to confirm
ç
M
to cancel
SERV
12:30
Alternate
with
968
12:30
The device is in service: it delivers softened water.
Its treatment autonomy before regeneration is here 968 liters.
REMPL
375
Water is being poured into the salt tank (see chapter AD-
VANCED SETTING), it will end in 375 seconds.
SAUM
180
The brine is under preparation in the salt tank for the next
regeneration; this step will end here in 180 minutes.
REGE 1
00:45
The softener is going through its first active regeneration step,
which will end here in 0 minutes and 45 seconds.
REGE 2
18:35
The softener is going through its second active regeneration
step, which will end here in 18 minutes and 35 seconds.
REGE 3
02:15
The softener is going through its third active regeneration step,
which will end here in 02 minutes and 15 seconds.
CHECK
Alternate
with
SALT
The softener detects a lack of salt and advises to check the salt
level in the salt tank.
STD-BY
12:30
Alternate
with
968
12:30
The regeneration function is OFF (see Stand-By mode next
page). The softener delivers soft water as long as its autonomy
allows it (here: autonomy of 968 liters).
MANUAL REGENERATION
At any time, it is possible to trigger the rege-
neration of the softener, via the long press (5
seconds) on the
OK
key.
If this is done for a test purpose, it is possible to
manually go from one step to the next by briefly
pressing the
OK
key.
SALT ALARM ACKNOWLEDGEMENT
When no salt is left in the tank, the device
displays the alternate words
SALT
and
CHECK
.
Once the salt refill is done, you may just wait for
the next regeneration to let this alarm disappear.
It is recommended though to acknowledge
immediately the alarm, following these steps:
• Proceed with a long press (5 seconds) on the
M
key
• Then briefly press this
M
key to go through
the menus until the display shows this one:
CHECK / SALT
(alternate)
On
• Press once on
ê
or
é
key to make
OFF
appear
on the lower line
• Press
OK
to confirm
• Press
M
during 5 seconds to quit the menu:
the alarm shall disappear
POWER CUT
In case of a power cut during a regeneration, this
process restarts at the beginning of the ongoing
step. In case of a power cut during service, the
softener will restart also in service.
STAND-BY MODE
It is possible to prevent the softener from going
through a regeneration, automatic or manual.
This might be useful, for example, while you are
waiting for the intervention of a technician in
case of technical problem. Therefore:
• Proceed with a long press (5 seconds) on the
M
key
• Then briefly press this
M
key to go through
the menus until the display shows this one:
STD-BY
Off
• Press once on
ê
or
é
key to make
ON
dis-
played on the lower line
• Press
OK
to confirm
The display shows then the message
STD-BY
alternating with the softener autonomy value.
To cancel this function, you just have to come
back to this
STAND-BY
menu and turn the lower
line into
OFF
.