BWT 821002 Fitting And Operating Instructions Download Page 97

IT

97

L’apparecchio di osmosi inversa viene fornito completo di:

Controllo a microprocessore:

1

¬ ¬$ISPLAY¬/,%$¬MONOCROMATICO 

2

¬ ¬4ASTO¬DI¬FUNZIONE¬!CCESO¬¬SPENTO¬E¬PAUSA

3

¬ ¬4ASTO¬DI¬FUNZIONE¬)N¬ALTO

4

¬ ¬4ASTO¬DI¬FUNZIONE¬)N¬BASSO

5

¬ ¬4ASTO¬DI¬FUNZIONE¬#ONFERMA%NTER

6

¬ ¬4ASTO¬DI¬FUNZIONE¬2ETURNINDIETRO¬AL¬MENU¬PRECEDENTE

7

¬ ¬$UO#OLOR,%$¬ROSSOVERDE

Attacchi ed elementi di servizio:

8

¬¬¬

¬5SCITA¬PERMEATO¬Œ¬MM 

9

¬¬¬

¬5SCITA¬CONCENTRATO¬Œ¬MM 

10

 

¬%NTRATA¬ACQUA¬NON¬TRATTATA

¬

–h¬OPPURE¬Œ¬MM 

11

¬

¬#AVO¬DI¬COLLEGAMENTO¬ELETTRICO¬CON¬PRESA¬3CHUKOu#%%h

12

¬¬

6ALVOLA¬DI¬MISCELAZIONE¬2EGOLAZIONE¬SOLO¬TRAMITE¬SERVIZIO¬

¬¬¬¬¬DASSISTENZA¬"74¬3ERVICE 

Disponibile opzionalmente, Numero d‘ordine 823428:

13

¬¬+IT¬DI¬MONTAGGIO¬DI¬CAVI¬PER¬ALLARME¬ESTERNO¬/54054

¬

¬¬¬¬¬¬CON¬CONNETTORE¬-¬A¬¬POLI¬PER¬L@USCITA¬DI¬ALLARME¬$/

1.3 Indirizzo del produttore

,A¬PRODUZIONE¬DEGLI¬APPARECCHI¬"74¬BESTAQUA¬¬¬
AVVIENE¬PER¬CONTO¬DELLA¬

BWT water + more GmbH

7ALTER3IMMER3TRA”E¬
!4¬-ONDSEE
4EL¬¬

&AX¬¬

%-AIL¬¬WAREWASHING BWTGROUPCOM

1.4 Informazioni generali

)L¬ -ANUALE¬ DUSO¬ E¬ )NSTALLAZIONE¬ )-5 ¬ CONTIENE¬ INFORMAZIONI¬
IMPORTANTI¬RIGUARDANTI¬LA¬GESTIONE¬SICURA¬ED¬EFlCACE¬DELLOSMOSI¬
INVERSA¬¬"74¬BESTAQUA¬¬¬,E¬)-5¬SONO¬PARTE¬INTEGRANTE¬
DELL@APPARECCHIO¬E¬DEVONO¬ESSERE¬CONSERVATE¬NEI¬PRESSI¬DELLO¬
STESSO¬PER¬ESSERE¬SEMPRE¬A¬DISPOSIZIONE¬DEL¬PERSONALE¬OPERATIVO

1.4.1 Lettura del istruzioni di montaggio e per l‘uso

)L¬PERSONALE¬DEVE¬AVER¬LETTO¬ATTENTAMENTE¬IL¬PRESENTE¬)-5¬PRIMA¬DI¬
INIZIARE¬QUALSIASI¬LAVORO¬E¬DEVE¬AVERNE¬COMPRESO¬IL¬CONTENUTO¬)L¬
REQUISITO¬FONDAMENTALE¬PER¬LAVORARE¬IN¬SICUREZZA¬Ò¬L@OSSERVANZA¬
DI¬TUTTE¬LE¬AVVERTENZE¬PER¬LA¬SICUREZZA¬E¬DELLE¬ISTRUZIONI¬DI¬LAVORO¬
INDICATE

6ALGONO¬INOLTRE¬LE¬NORME¬ANTINFORTUNISTICHE¬IN¬VIGORE¬NEL¬LUOGO¬
DI¬IMPIEGO¬DELLAPPARECCHIO¬COSI¬COME¬LE¬NORME¬GENERALI¬DI¬
SICUREZZA¬,E¬lGURE¬CONTENUTE¬NELLE¬PRESENTI¬ISTRUZIONI¬SERVONO¬
A¬FACILITARE¬LA¬COMPRENSIONE¬DELLE¬STESSE¬E¬POSSONO¬DIVERGERE¬
DALL@EFFETTIVA¬VERSIONE¬DELL@APPARECCHIO

1.2 In dotazione

,IMPIANTO¬DI¬OSMOSI¬INVERSA¬"74¬BESTAQUA¬¬¬CONSISTE¬¬
IN¬¬COMPONENTI¬BASE¬

s¬5NIT̬DI¬MISURAZIONE¬E¬COMANDO

s¬0OMPA¬AD¬ALTA¬PRESSIONE

s¬-EMBRANE¬DI¬OSMOSI¬INVERSA¬NEL¬RECIPIENTE¬¬

A¬PRESSIONE¬PER¬LESERCIZIO¬ONOFmINE

Fig. 1:

¬

BWT bestaqua 14 - Lato frontale dell’apparecchio

Fig. 2:

¬

BWT bestaqua 18 - Lato posteriore dell‘apparecchio

1

2

7

6

4

10

8

9

12

11

13

3

5

Summary of Contents for 821002

Page 1: ...Einbau und Bedienungsanleitung DE Fitting and operating instructions EN Notice de montage et d utilisation FR Istruzioni di montaggio e per l uso IT BWT bestaqua 14 BWT bestaqua 18...

Page 2: ...JCV QW JCXG UJQYP KP WU by purchasing a BWT appliance 0QWU XQWU TGOGTEKQPU FG NC EQP ance dont vous nous t moignez par l achat d un appareil BWT 8K TKPITC KCOQ RGT NC FWEKC accordataci acquistando un...

Page 3: ...n des Speisewassers 8 1 7 3 Optimaler Betriebsdruck 8 Kapitel 2 Installation und Montage 9 2 1 Einbau und Inbetriebnahme 9 Kapitel 3 Betrieb und Softwaresteuerung 10 3 1 bersicht zur Ger testeuerung 1...

Page 4: ...werden bevor es der RO zugef hrt werden kann RO Abk rzung f r Reverse Osmose Umkehrosmose Permeat Das weitgehend entsalzte durch Umkehrosmose gewonnene Reinwasser Kenngr e ist die elektrische Leitf h...

Page 5: ...ige Hinweise f r den sicheren und ef zienten Umgang mit der Um kehrosmose BWT bestaqua 14 18 Die EBA ist Bestandteil des Ger tes und in seiner unmittelbaren N he jederzeit zug nglich f r das an und mi...

Page 6: ...sind Achtung Gefahrenstelle Angaben bzw Ge und Verbote zur Verh tung von Personen oder umfangreichen Sachsch den Beachte Hebt n tzliche Tipps und Empfehlungen sowie Informationen f r einen ef zienten...

Page 7: ...r Bef llung des produzierten Permeates in einen atmosph rischen Tank verwendet werden F r eine anwendungsbedingte Einstellung der Wasserqualit t bietet das Ger t die M glichkeit das entsalzte Wasser m...

Page 8: ...st ndige Materialien verwendet werden Elektrische St reinf sse Die St raussendung Spannungsspitzen hochfrequente elektro magnetische Felder St r und Spannungsschwankungen durch die umgebende Elektroi...

Page 9: ...nd Inbetriebnahme Nehmen Sie Ihr Ger t aus der Verpackung und pr fen Sie die Lieferung auf Vollst ndigkeit und etwaige Transportsch den Hydraulische Installation Beachten Sie die allgemeinen Installat...

Page 10: ...r n rot zeigt den Ger tezustand an s Gr ne LED f r aktivierte Netzspannung LINE s Rote LED f r Fehlermeldungen FAILURE Hinweise zum Display Hinweis Das Display schaltet sich nach 120s aus Hinweis Das...

Page 11: ...Taste ca 2s gedr ckt gehalten wird schaltet das Ger t vollst ndig aus 3 4 Aktivierter Betriebsmodus PERMEAT 1975 ml min KONZENTRAT 1190 ml min WCF SOLLWERT 62 COND 12 S TEMP 17 C WCF 62 PUMP DRUCK PER...

Page 12: ...GEN besteht aus vier ausw hlbaren Men punkten in denen nachfolgende Ein stellungen vorgenommen werden k nnen ALLGEMEIN s LLGEMEINE INSTELLUNGEN ATUM 5HRZEIT ANDESSPRACHE DRUCK s 3OLL UND RENZWERTE F R...

Page 13: ...CHE UHRZEIT 01 26 UHRZEIT 11 26 UHRZEIT 11 26 UHRZEIT 15 26 UHRZEIT 15 42 X DATUM X ZEIT X SPRACHE ENGLISH DEUTSCH FRANCAIS SPRACHE Sprache Langue ENGLISH DEUTSCH FRANCAIS SPRACHE Sprache Langue ENGLI...

Page 14: ...AEHIGKEIT Leitwert in S cm z EINSTELLUNG WCF Permeatausbeute WCF Men Abb 12 Men ebene 1 EINSTELLUNGEN F hren Sie die Allgemeinen Einstellungen des im Men zweig EINSTELLUNGEN DRUCK entsprechend Abb 14...

Page 15: ...SCHALTVERZOEGERUNG 1 6 BAR Sollwert Stopp Druck 3 6 BAR Sollwert Stopp Druck 3 5 BAR Sollwert Stopp Druck 3 5 BAR Sollwert Stopp Druck 3 5 BAR Sollwert Stopp Druck X EINSCHALTDRUCK X AUSSCHALTDRUCK X...

Page 16: ...M LEITFAEHIGKEIT Leitwert Alarm Abb 17 Men ebene 2 EINSTELLUNGEN LEITFAEHIGKEIT Hinweis F r den Fall dass Sie die Einstellung STOP aktivieren m ssen Sie das Ger t ausschalten und wieder einschalten Hi...

Page 17: ...LEITFAEHIGKEIT Leitwert in S cm z EINSTELLUNG WCF Permeatausbeute WCF Men Abb 20 Men ebene 1 EINSTELLUNGEN Bet tigen Sie erneut die Taste um die WCF Sollwerte einzustellen Beachte Es ist nur m glich E...

Page 18: ...e Passwortgesch tzte Parameter X PASSWORT Systempasswort Passworteingabe PASSWORTEINGABE BWT Service Bitte jede Ziffer einzeln mit den Pfeil hoch Pfeil herunter Tasten anw hlen und dann jede Ziffer ei...

Page 19: ...n INSTALLATION k nnen Sie entsprechend der nachfolgenden bersicht Men struktur Abb 27 Abb 28 Abb 29 durchf hren Hinweis Die Einstellungen im Men INSTALL ATION d rfen nur von fachkundigen und unterwies...

Page 20: ...rt max Start Druck 2 5 BAR Sollwert max Start Druck 2 5 BAR Sollwert max Start Druck 2 1 BAR Sollwert max Start Druck 2 1 BAR Sollwert max Start Druck X WCF MIN X WCF MAX X MAX AUSSCHALTDRUCK X MAX EI...

Page 21: ...100 SEK Sollwert Spuelzeit 000 SEK Sollwert Spuelzeit 000 SEK Sollwert Spuelzeit 030 SEK Sollwert Spuelzeit 030 SEK Sollwert Spuelzeit Abb 28 Abb 29 Men struktur INSTALLATION 3 3 Installation X WCF M...

Page 22: ...NG Die manuelle Sp lung beginnt sofort DDas Ger t sp lt manuell Nach der Men punkt Anwahl von MANUELLE SPUELUNG sp lt das Ger t Die ausgef hrten Hygienesp lungen reduzie ren Stillstandkontaminationen...

Page 23: ...N X AKTIV NICHT AKTIV X UHRZEIT SPUELUNG AKTIV NICHT AKTIV AKTIV NICHT AKTIV AKTIV NICHT AKTIV Abb 32 Men struktur SERVICE Wartung X AKTIV NICHT AKTIV X UHRZEIT SPUELUNG UHRZEIT 23 35 UHRZEIT 03 35 UH...

Page 24: ...werden 4 1 Fehlerbehebung Beachte Funktioniert Ihr RO Ger t nicht so wie es soll dann gehen Sie die untenstehende Fehlermeldungs Liste sowie die Check Liste Abs 4 2 auf der Seite 26 Punkt f r Punkt du...

Page 25: ...SURE TRANSMITTER FAILURE FAULT 4 MAX PRESSURE TRANSMITTER FAILURE FAULT 4 FEHLERMELDUNG 4 bei Betrieb FEHLERMELDUNG 4 bei Start 4 MAX PRESSURE TRANSMITTER FAILURE s EHLER AXIMALDRUCK DES Drucksensors...

Page 26: ...r den Fall dass das Problem weiterhin bestehen bleibt rufen Sie Ihren H ndler oder den lokalen Kundendienst an 4 1 Fehlerbehebung Beachte Funktioniert Ihr RO Ger t nicht so wie es soll dann gehen Sie...

Page 27: ...tervall Allgemeine visuelle Inspektion Kunde w chentlich berpr fen der Dichtheit Kunde w chentlich Reinigung mit feuchtem Tuch Kunde nach Bedarf Leitf higkeit Wert angezeigt am RO Display Kunde w chen...

Page 28: ...OUTPUT erm glicht die Verwendung eines potentialfreien Kontaktes f r den Alarm ausgang Alle Ger tealarme lassen sich so als Sammelalarm auf eine externe Steuerung bertragen Das Kabelset f r externe Al...

Page 29: ...ntilausf hrung 230VAC Steckernorm geerdeter PE Netz Stecker Schuko CEE7 Speisewasser Permeat Konzentratanschluss Zoll mm mm 3 4 oder 10 mm 8 8 Dimensionen Breite Tiefe H he B x T x H mm 390 x 540 x 15...

Page 30: ...deter PE Netz Stecker Schuko CEE7 Speisewasser Permeat Konzentratanschluss Zoll mm mm 3 4 oder 10 mm 8 8 Dimensionen Breite Tiefe H he B x T x H mm 390 x 540 x 390 Gewicht kg 20 Bestellnummer BWT wate...

Page 31: ...ng 500 S cm ALARM LEITFAEHIGKEIT Deaktiviert ALARM Werkseinstellung ALARM WCF Vorgabe Wert set point Bereich 59 79 Werkseinstellung 50 WCF MIN Bereich 20 59 Werkseinstellung 40 WCF MAX Bereich 50 79 W...

Page 32: ...VJCV QW JCXG UJQYP KP WU by purchasing a BWT appliance 0QWU XQWU TGOGTEKQPU FG NC EQP ance dont vous nous t moignez par l achat d un appareil BWT 8K TKPITC KCOQ RGT NC FWEKC accordataci acquistando u...

Page 33: ...s 38 1 7 3 Setting the correct operating pressure 38 Chapter 2 Assembly and installation 39 2 1 Preparation for assembly 39 Chapter 3 Operation and programming of the software 40 3 1 Quick operation g...

Page 34: ...RO device RO Abbreviation for Reverse Osmosis Permeate The largely desalinated pure water ltered in the RO mem branes and generated by reverse osmosis The characteristic value is the electric conduct...

Page 35: ...alarm contact OUTPUT with M8 connector for the alarm output DO 1 3 Manufacturer The RO devices BWT bestaqua 14 18 are manufactured in the name of BWT water more GmbH Walter Simmer Stra e 4 AT 5310 Mo...

Page 36: ...tails or orders and prohibitions to avoid personal injury or extensive damage to property Please observe Underlines useful recommendations and information for an ef cient operation free of any interru...

Page 37: ...permeate into an atmospheric tank An integrated mixing valve enables blending of permeate and feed water in a precise manner to obtain a required product water conductivity depending on the applicatio...

Page 38: ...he local feed water quality Quality of the pipeline supply Please observe Only corrosion resistant material must be used in the permeate area Electrical interference The emission of interference volta...

Page 39: ...the device from its packaging and check the delivery to see that everything is there and that no damage was caused during transport Hydraulic installation Please respect the general installation inst...

Page 40: ...us of the device s Green LED for activated mains voltage LINE s Red LED for failure messages FAILURE Comments on the display Note The display always switches OFF after 120s Note The menu FACTORY DEFAU...

Page 41: ...device completely by pressing the ON OFF key for about 2s on the control unit 3 4 Menu display of the activated system PERMEATE 1975 ml min CONCENTRATE 1190 ml min WCF SET POINT 62 COND 12 S TEMP 17...

Page 42: ...ectable menu items in which the subsequent settings may be effected GENERAL s ENERAL DEVICE SETTINGS DATE TIME LANGUAGE PRESSURE s 3ET POINT AND LIMIT VALUES FOR PRESSURE CONDUCTIVITY s 3ET POINT AND...

Page 43: ...X LANGUAGE TIME 01 26 TIME 11 26 TIME 11 26 TIME 15 26 TIME 15 42 X DATE X TIME X LANGUAGE ENGLISH DEUTSCH FRANCAIS Language Sprache Langue ENGLISH DEUTSCH FRANCAIS Language Sprache Langue ENGLISH DE...

Page 44: ...z CONDUCTIVITY Conductivity value S cm z WCF SETUP Permeate output yield WCF menu Fig 12 Menu Level 1 Settings Perform the general settings of the Settings PRESSURE selection menu in accordance with F...

Page 45: ...TIME DELAY 1 6 BAR Stop pressure 3 6 BAR Stop pressure 3 5 BAR Stop pressure 3 5 BAR Stop pressure 3 5 BAR Stop pressure X START PRESSURE X STOP PRESSURE X STOP TIME DELAY 01 sec Stop time delay 11 s...

Page 46: ...TY LIMIT Conductivity limit value ACTIVE X CONDUCTIVITY ALARM Conductivity alarm Fig 17 Menu Level 2 Settings CONDUCTIVITY Note In case you activate the STOP setting you have to deactivate and then ac...

Page 47: ...ate z CONDUCTIVITY Conductivity value S cm z WCF SETUP Permeate output WCF ACTIVE Fig 20 Menu Level 1 Settings Press again the key to adjust the set points of the WCF menu Please observe It is only po...

Page 48: ...tected parameters X PASSWORD System password Enter the password PASSWORD ENTRY BWT Service Please select and set each digit individually Firstly by selection with the arrow up and arrow down keys and...

Page 49: ...menu according to the following overview menu structure of Fig 27 Fig 28 Fig 29 Note The settings in the INSTALLATION menu may only be effected by quali ed and instructed persons Please observe The s...

Page 50: ...BAR Set max start pressure 2 5 BAR Set max start pressure 2 5 BAR Set max start pressure 2 1 BAR Set max start pressure 2 1 BAR Set max start pressure X WCF MIN X WCF MAX X PRESSURE STOP MAX X PRESSUR...

Page 51: ...SSURE X RINSE TIME X WATER FILL UP TIME 100 sec Rinse time 000 sec Rinse time 000 sec Rinse time 030 sec Rinse time 030 sec Rinse time Fig 28 Fig 29 Programming procedure INSTALLATION 3 3 X WCF MIN X...

Page 52: ...NING Cleaning deactivated X DISINFECTION Disinfection deactivated Fig 31 Menu Level 1 Maintenance Adjustment for MANUAL RINSING ATTENTION The manual ushing begins immediately DThe RO unit rinses manua...

Page 53: ...z DISINFECTION X ENABLE DISABLE X RINSE HOUR ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE Fig 32 Programming procedure MAINTENANCE X ENABLE DISABLE X RINSE HOUR TIME 23 35 TIME 03 35 TIME 02 35 TIME...

Page 54: ...NING Cleaning deactivated X DISINFECTION Disinfection deactivated Fig 31 Menu Level 1 Maintenance Adjustment for MANUAL RINSING ATTENTION The manual ushing begins immediately DThe RO unit rinses manua...

Page 55: ...z DISINFECTION X ENABLE DISABLE X RINSE HOUR ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE Fig 32 Programming procedure MAINTENANCE X ENABLE DISABLE X RINSE HOUR TIME 23 35 TIME 03 35 TIME 02 35 TIME...

Page 56: ...socket wrench 3mm 4 1 Trouble shooting guide Please observe If your reverse osmosis is not performing as it should please run through the alarm messages below and the check list Part 4 2 on page 26 In...

Page 57: ...MAX PRESSURE TRANSMITTER FAILURE FAULT 4 FAULT 4 in operation FAULT 4 during starting 4 MAX PRESSURE TRANSMITTER FAILURE s AILURE OF THE MAXIMUM PRESSURE OF THE pressure sensor s 0RESSURE TRANSMITTER...

Page 58: ...set the present time Note If the problem persists please call your local dealer or after sales service team 4 1 Trouble shooting guide Please observe If your reverse osmosis is not performing as it sh...

Page 59: ...omer Weekly Check of tightness Customer Weekly Cleaning with a moist cloth Customer As required Conductivity value displayed by RO Customer Weekly Conductivity value of measuring device Customer servi...

Page 60: ...UT enables the use of the potential free contact for the alarm output All RO alarms can be transferred as an common alarm to an external control The Cable kit for external alarm contact OUTPUT is eith...

Page 61: ...n operation standby W 460 3 Type of valve 230VAC Standard of connector grounded PE mains plug Three pin CEE7 Feed water permeate concentrate connection inch mm mm 3 4 or 10mm 8 8 Dimensions Width dept...

Page 62: ...valve 230VAC Standard of connector grounded PE mains plug Three pin CEE7 Feed water permeate concentrate connection inch mm mm 3 4 or 10mm 8 8 Dimensions Width depth height W x D x H mm 150 x 540 x 3...

Page 63: ...NDUCTIVITY LIMIT S cm Default setting 500 S cm CONDUCTIVITY ALARM DISABLED ALARM Default setting ALARM enabeld WCF set point Range 20 79 Default setting 50 WCF MIN Range 20 59 Default setting 40 WCF M...

Page 64: ...VJCV QW JCXG UJQYP KP WU by purchasing a BWT appliance 0QWU XQWU TGOGTEKQPU FG NC EQP ance dont vous nous t moignez par l achat d un appareil BWT 8K TKPITC KCOQ RGT NC FWEKC accordataci acquistando u...

Page 65: ...d alimentation 70 1 7 3 R glage optimal de la pression de fonctionnement 70 Chapitre 2 Montage et installation 71 2 1 Installation et mise en service 71 Chapitre 3 Fonctionnement et programmation du l...

Page 66: ...pour tre ainsi utilisable par le syst me de d mi n ralisation par osmose inverse RO Abr viation pour Reverse Osmose osmose inverse OI Perm at L eau pure acquise par osmose inverse largement d min rali...

Page 67: ...ortants pour le maniement s r et ef cient de l osmose inverse BWT bestaqua 14 18 La NMU fait partie de l appareil et doit tre conserv e proximit et accessible tout moment pour le personnel travaillant...

Page 68: ...nformations prescriptions et interdictions ayant pour but la pr vention des accidents corporels et mat riels Remarque Met en valeur des informations et recom mandations utiles pour un fonctionnement e...

Page 69: ...ange int gr e permet d introduire de l eau brute dans le perm at de mani re pr cise pour obtenir la production d une eau de conductivit requise en fonction de son application 6EUILLEZ CONSULTER LE R G...

Page 70: ...pointes de tension champs lectromagn tiques haute fr quence tensions parasites varia tions de tension d gag es par les installations lectriques proximit ne doivent pas d passer les valeurs maximales...

Page 71: ...E L EMBALLAGE V RIlEZ L INT GRALIT DE LA LIVRAISON ET ASSUREZ VOUS QUE LE MAT RIEL NE COMPORTE AUCUN DOMMAGE D AU TRANSPORT Installation hydraulique Respecter les prescriptions locales et les directiv...

Page 72: ...TENSION DU SECTEUR ACTIV E LINE 6OYANT lumineux rouge POUR MESSAGES D ERREUR FAILURE Indications sur l af chage Note AFlCHAGE S TEINT AU BOUT DE 120 sec Note E MENU FACTORY DEFAULT SETTINGS EST PROT...

Page 73: ...reil 3I L ON MAINTIENT APPUY E LA touche MARCHE ARR T env 2 sec L APPAREIL S TEINT COMPL TEMENT 3 4 Ecran de Menu du syst me activ PERMEAT 1975 ml min CONCENTRAT 1190 ml min WCF SET UP 62 COND 12 S TE...

Page 74: ...compose de quatre points de menu s lectionnables dans lesquels on peut entreprendre les r glages suivants GENERALE s 2 GLAGES G N RAUX DATE HEURES LANGUE PRESSION s 6ALEURS PRESCRITES ET LIMITES POUR...

Page 75: ...UE HEURES 01 26 HEURES 11 26 HEURES 11 26 HEURES 15 26 HEURES 15 42 X DATE X 52 X LANGUE ENGLISH DEUTSCH FRANCAIS Language Sprache Langue ENGLISH DEUTSCH FRANCAIS Language Sprache Langue ENGLISH DEUTS...

Page 76: ...erm at activ z CONDUCTIVITE Conductivit en S cm z AJUSTEMENT DE WCF Sortie perm at Menu rendement WCF Fig 12 Niveau de menu 1 AJUSTEMENTS 0ROC DEZ AUX R GLAGES G N RAUX DANS LE MENU AJUSTEMENTS PRESSI...

Page 77: ...ARRET 1 6 BAR Pression d arret 3 6 BAR Pression d arret 3 5 BAR Pression d arret 3 5 BAR Pression d arret 3 5 BAR Pression d arret X PRESSION DEMARRAGE X PRESSION D ARRET X DELAI D ARRET 01 sec Delai...

Page 78: ...d sactiver l alarme DE conductivit 2 me niveau de menu param tres r glables X LIMITE CONDUCTIVITE Valeur limite de conductivit X 2 5 4 6 4 Alarme de conductivit Fig 17 Niveau de menu 2 AJUSTEMENTS CON...

Page 79: ...r de conductivit S cm z AJUSTEMENT DE WCF Rendement de perm at menu WCF Fig 20 Niveau de menu 1 AJUSTEMENTS PPUYEZ DE NOUVEAU SUR LA touche POUR R GLER LES VALEURS DE CONSIGNE DANS LE MENU 7 Remarque...

Page 80: ...un mot de passe X MOT DE PASSE Mot de passe de syst me Entr e du mot de passe Entr e du mot de passe Service BWT S LECTIONNER ET R GLER CHAQUE CHIFFRE INDIVIDU ELLEMENT AVEC LES TOUCHES che en haut ch...

Page 81: ...UVEZ PROC DER AUX R GLAGES DANS LE MENU INSTALLATION SUIVANT 3TRUCTURE DU MENU Fig 27 Fig 28 Fig 29 TEL QUE PR SENT DANS L APER U Note ES R GLAGES DANS LE MENU INSTALLATION NE DOIVENT TRE FAITS QUE PA...

Page 82: ...5 BAR Valeur de consigne demarrage 2 5 BAR Valeur de consigne demarrage 2 5 BAR Valeur de consigne demarrage 2 1 BAR Valeur de consigne demarrage 2 1 BAR Valeur de consigne demarrage X WCF MIN X WCF M...

Page 83: ...PLISSAGE 100 sec Temps de rincage 000 sec Temps de rincage 000 sec Temps de rincage 030 sec Temps de rincage 030 sec Temps de rincage Fig 28 Fig 29 Proc dure de programmation INSTALLATION 3 3 X WCF MI...

Page 84: ...SINFECTION D sinfection d sactiv Fig 31 Niveau de menu 1 Maintenance Ajustement pour MANUAL RINSE Attention Le rin age manuel commence aussit t D L appareil rince manuellement 3 9 2 Menu SERVICE AUTOM...

Page 85: ...DESINFECTION X ACTIF PAS ACTIF X TEMPS RINCAGE ACTIF PAS ASTIF 4 PAS ASTIF ACTIF PAS ASTIF Fig 32 Proc dure de programmation SERVICE X ACTIF PAS ACTIF X TEMPS RINCAGE HEURES 23 35 HEURES 03 35 HEURES...

Page 86: ...PAS COMME IL DEVRAIT PARCOUREZ POINT PAR POINT LA liste des messages d erreurs CI DESSOUS AINSI QUE LA liste de v ri cation Par 4 2 LA page 26 N CAS DE PANNE LES TRAVAUX DE R PARATION NE PEUVENT TRE...

Page 87: ...MITTER FAILURE FAULT 4 MESSAGE D ERREUR 4 lors du fonctionnement MESSAGE D ERREUR 4 lors du d marrage 4 MAX PRESSURE TRANSMITTER FAILURE s RREUR i PRESSION MAXIMUM w DU TRANSMETTEUR DE PRESSION s 4RAN...

Page 88: ...PERSISTENT VEUILLEZ CONTACTER VOTRE REVENDEUR OU L QUIPE DE SERVICE APR S VENTE 4 1 Vue d ensemble des alarmes Remarque 3I VOTRE APPAREIL NE FONCTIONNE PAS COMME IL DEVRAIT PARCOUREZ POINT PAR POINT...

Page 89: ...AINE Contr le visuel de l tanch it LIENT UNE FOIS PAR SEMAINE Nettoyage avec un chiffon humide LIENT D S QUE N CESSAIRE Conductivit valeur af ch e sur l cran OI LIENT UNE FOIS PAR SEMAINE Conductivit...

Page 90: ...N DE L CONTACT LIBRE DE POTENTIEL DE LA SORTIE D ALARME 4OUTES LES ALARMES 2 PEUVENT TRE TRANSF R ES COMME UNE ALARME COMMUN UN CONTR LE EXTERNE kit de montage pour alarme contact externe OUTPUT EST S...

Page 91: ...3TANDARD DES CONNECTEURS i 0 CONTACT DE MISE LA TERRE w LECTRIQUE lCHE i w 2ACCORDEMENTS EAU BRUTE PERM AT CONCENTRAT POUCES MM h OU MM IMENSIONS LARGEUR PROFONDEUR HAUTEUR X 0 X MM X X 0OIDS OP RATI...

Page 92: ...RRE w LECTRIQUE lCHE i w 2ACCORDEMENTS EAU BRUTE PERM AT CONCENTRAT POUCES MM h OU MM IMENSIONS LARGEUR PROFONDEUR HAUTEUR X 0 X MM X X 0OIDS OP RATIONNEL KG Num ro de commande BWT water more GmbH AT...

Page 93: ...E Inactifs ALARME R glage d usine ALARM Valeur prescrite WCF set point Plage 59 79 R glage d usine 50 WCF MIN Plage 20 59 R glage d usine 40 WCF MAX Plage 50 79 R glage d usine 60 Pression de mise en...

Page 94: ...VJCV QW JCXG UJQYP KP WU by purchasing a BWT appliance 0QWU XQWU TGOGTEKQPU FG NC EQP ance dont vous nous t moignez par l achat d un appareil BWT 8K TKPITC KCOQ RGT NC FWEKC accordataci acquistando u...

Page 95: ...MINIMI DI MONTAGGIO UOGO D INSTALLAZIONE ONDIZIONI ARATTERISTICHE DELL ACQUA DI ALIMENTAZIONE 0RESSIONE D ESERCIZIO OTTIMALE Capitolo 2 Installazione e montaggio 101 NSTALLAZIONE E MESSA IN SERVIZIO...

Page 96: ...DI DISSALAZIONE RO OI BBREVIAZIONE PER 2EVERSE SMOSE OSMOSI INVERSA Permeato ACQUA GREZZA GENERALMENTE ACQUA POTABILE NON PRETRATTATA DEVE ESSERE SOTTOPOSTA AD UN PRETRATTAMENTO GENERALMENTE ADDOLCIME...

Page 97: ...I RIGUARDANTI LA GESTIONE SICURA ED EFlCACE DELL OSMOSI INVERSA 74 BESTAQUA E 5 SONO PARTE INTEGRANTE DELL APPARECCHIO E DEVONO ESSERE CONSERVATE NEI PRESSI DELLO STESSO PER ESSERE SEMPRE A DISPOSIZIO...

Page 98: ...E DI DANNI ESTESI ALLE COSE E ALLE PERSONE Osservare VIDENZIA CONSIGLI E RACCOMANDAZIONI COS COME INFORMAZIONI UTILI PER UN ESERCIZIO EFlCIENTE E PRIVO DI PROBLEMI Avvertenza NFORMAZIONI AGGIUNTIVE PE...

Page 99: ...UN SERBATOIO ATMOSFERICO CON IL PERMEATO PRODOTTO 0ER L IMPOSTAZIONE DELLA QUALIT DELL ACQUA A SECONDA DELL IMPIE GO IL DISPOSITIVO OFFRE LA POSSIBILIT DI MISCELARE IN MODO PRECISO L ACQUA DISSALATA C...

Page 100: ...TANTO materiali resistenti alla corrosione Interferenze elettriche EMISSIONE DELLE INTERFERENZE PICCHI DI VOLTAGGI CAMPI ELETTRO MAGNETICI DI ALTA FREQUENZA VOLTAGGI DI INTERFERENZE FUTTUAZIONI DI VOL...

Page 101: ...2 1 Installazione e messa in servizio 4OGLIERE IL PROPRIO APPARECCHIO DALL IMBALLAGGIO E CONTROLLARE LA FORNITURA PER COMPLETEZZA ED EVTL DANNI DA TRASPORTO Collegamento idraulico Osservare le indicaz...

Page 102: ...ONE ELETTRICA ATTIVATA LINE s LED rosso 0ER SEGNALAZIONI D ERRORE FAILURE Indicazioni sul display Avvertenza L DISPLAY SI SPEGNE DOPO 120s Avvertenza L ENU IMPOST DI FABBRICA PROTET TO DA UNA PAROLA D...

Page 103: ...SERVIZIO Spegnere l apparecchio 4ENENDO PREMUTO ca 2s IL tasto ACC SPEN L APPARECCHIO SI SPEGNE COMPLETAMENTE 3 4 Modalit di servizio attivato PERMEAT 1975 ml min CONCENTRAT 1190 ml min WCF SET UP 62...

Page 104: ...i selezionabili dal men stesso da cui possono poi essere effet tuate le seguenti impostazioni GENERALE s MPOSTAZIONI GENERALI DATA ORA LINGUA REG PRESSIONE s 6ALORI SETTING E DI LIMITE DELLA PRESSIONE...

Page 105: ...15 26 ORA15 42 X DATA X 2 X LINGUA ENGLISH DEUTSCH FRANCAIS Language Sprache LINGUA ENGLISH DEUTSCH FRANCAIS Language Sprache LINGUA ENGLISH DEUTSCH FRANCAIS Language Sprache LINGUA ENGLISH DEUTSCH F...

Page 106: ...to ATTIVO z 5 4 Conducibilita in S cm z SETTAGGIO WCF Rendimento Permeato Men WCF Fig 12 Livello di menu 1 RETTIFICHE SEGUIRE LE IMPOSTAZIONI GENERALI NELLA PARTE DEL MENU RETTIFICHE PRESSIONE SEGUEND...

Page 107: ...RITARDO DOPO 1 6 BAR Valore di Stop Pressione 3 6 BAR Valore di Stop Pressione 3 5 BAR Valore di Stop Pressione 3 5 BAR Valore di Stop Pressione 3 5 BAR Valore di Stop Pressione X START PRESSIONE X S...

Page 108: ...onducibilita X ALLARME CONDUCIBIILITA Valore limite allarme Fig 17 Livello di menu 2 RETTIFICHE CONDUCIBIILITA Avvertenza EL CASO SI ATTIVASSE L IMPOSTAZIONE STOP L APPARECCHIO DEVE ESSERE SPENTO E RI...

Page 109: ...DUCIBIILITA Conducibilita in S cm z SETTAGGIO WCF Rendimento Permeato Men WCF Fig 20 Livello di menu 1 RETTIFICHE ZIONARE NUOVAMENTE IL tasto PER RETTIlCARE I VALORI DI SETTING DEL 7 Osservare 3I POSS...

Page 110: ...tro protetto da password X PASSWORD Parola d ordine di sistema Inserimento Parola d ordine Inserimento PW BWT Service 3ELEZIONARE OGNI CIFRA SINGOLARMENTE CON I TASTI FRECCIA freccia su Freccia gi PER...

Page 111: ...STALLAZIONE E RETTIlCHE NEL MEN RETTIlCHE DI INSTALLAZIONE POSSONO ESSERE ESEGUITE SEGUENDO LA GRAlCA DELLA STRUTTURA MEN SOTTO INDICATA ALLE Fig 27 Fig 28 Fig 29 Avvertenza E RETTIlCHE NEL MEN INSTAL...

Page 112: ...sione Start 2 5 BAR Setting max Pressione Start 2 5 BAR Setting max Pressione Start 2 1 BAR Setting max Pressione Start 2 1 BAR Setting max Pressione Start X WCF MIN X WCF MAX X MAX PRESSIONE SPEGNI X...

Page 113: ...Setting tempo risciacquo 000 SEC Setting tempo risciacquo 030 SEC Setting tempo risciacquo 030 SEC Setting tempo risciacquo Fig 28 Fig 29 Struttura del menu INSTALLAZIONE 3 3 Installazione X WCF MIN X...

Page 114: ...gio manuale si avvia immediatamente D L apparecchio risciacqua manualmente Selezionata la voce del menu RISCIACQUO MANUALE l apparecchio esegue il lavaggio I lavaggi igienici eseguiti riducono le cont...

Page 115: ...ZIONE X ATTIVO NON ATTIVO X 2 2 3 15 44 6 NON ATTIVO 44 6 NON ATTIVO ATTIVO NON ATTIVO Fig 32 Struttura del menu SERVICE Manutenzione di assistenza X 44 6 44 6 X ORA RISCIACQUO ORA 23 35 ORA 03 35 ORA...

Page 116: ...a brugola 3mm 4 1 Eliminazione dei guasti Osservare 3E IL SUO DISPOSITIVO NON FUNZIONASSE NEL MODO DOVUTO CONTROLLI PUNTO PER PUNTO LA lista delle segnalazioni d errore SOTTOSTANTE E LA check list Par...

Page 117: ...TER FAILURE FAULT 4 MAX PRESSURE TRANSMITTER FAILURE FAULT 4 Segnalazione d Errore 4 durante l esercizio Segnalazione d Errore 4 all avvio 4 MAX PRESSURE TRANSMITTER FAILURE s RRORE 3ENSORE 0RESSIONE...

Page 118: ...ORARIO Avvertenza 3E IL PROBLEMA PERSISTE CONTATTATE IL VOSTRO DISTRIBUTORE O IL SERVIZIO D ASSISTENZA LOCALE 4 1 Eliminazione dei guasti Osservare 3E IL SUO DISPOSITIVO NON FUNZIONASSE NEL MODO DOVUT...

Page 119: ...ENTE 3ETTIMANALE Pulizia con un panno umido LIENTE LL OCCORRENZA Conduttivit Valore indicato sul display OI LIENTE 3ETTIMANALE Conduttivit Valore indicato sullo strumento di misura LIENTE 3ERVIZIO D A...

Page 120: ...NE Set di Cavi per allarmi esterni OUTPUT D LA POS SIBILIT DI USARE UN CONTATTO LIBERO DA POTENZIALE PER L USCITA DI ALLARME 4UTTI GLI ALLARMI DELL APPARECCHIO POSSONO ESSERE COSI TRASMESSI COME ALLAR...

Page 121: ...ORMA PRESA SPINA ELETTRICA CON MESSA A TERRA 0 CAVO DI ALIMENTAZIONE CON PRESA 3CHUKO u h IAMETRO ACQUA DI ALIMENTAZIONE PERMEATO CONCENTRATO POLLICI MM MM h OPPURE MM IMENSIONI LARGHEZZA X PROFONDIT...

Page 122: ...A A TERRA 0 CAVO DI ALIMENTAZIONE CON PRESA 3CHUKO u h IAMETRO ACQUA DI ALIMENTAZIONE PERMEATO CONCENTRATO POLLICI MM MM h OPPURE MM IMENSIONI LARGHEZZA X PROFONDITA X ALTEZZA X 0 X MM X X 0ESO D ESER...

Page 123: ...stazione di fabbrica 60 MAX PRESSIONE AVVIO PRESSURE START MAX Campo di valori 1 0 7 0 bar Impostazione di fabbrica 2 0 bar MAX PRESSIONE STOP PRESSURE STOP MAX Campo di valori 1 0 7 0 bar Impostazion...

Page 124: ...ER Seriennummer gr er als SIEHE 4YPENSCHILD 4ECHNISCHE ATEN und MIT EINER Bestellnummer SIEHE 4YPENSCHILD 4ECHNISCHE ATEN in bereinstimmung ZU DEN EG Richtlinien KONSTRUIERT HERGESTELLT UND ENDGEFERTI...

Page 125: ...003 WITH A serial number higher than SEE RATING PLATE TECHNICAL SPECIlCATIONS and WITH A order No SEE RATING PLATE TECHNICAL SPECIlCATIONS HAVE BEEN designed manufactured AND assembled ACCORDING TO TH...

Page 126: ...UN num ro de fabrication et d identi cation VOIR LES SP CIlCATIONS TECHNIQUES EST CON U FABRIQU ET ASSEMBL EN conformit avec les directives CE 2004 108 CE OMPATIBILIT LECTROMAGN TIQUE 2006 95 CE A DIR...

Page 127: ...ione no VEDI PLACCA E SPECIlCHE TECNICHE E stato progettato PRODOTTO E ASSEMBLATO A SECONDA DELLE seguenti Direttive EC LINE GUIDA 2004 108 EC INEE GUIDA PER BASSO VOLTAGGIO 6 2006 95 EC INEE GUIDA PE...

Page 128: ......

Page 129: ......

Page 130: ...water and more de Switzerland BWT AQUA AG Hauptstrasse 192 CH 4147 Aesch BL Phone 41 61 75588 99 Fax 41 61 75588 90 E Mail info bwt aqua ch France BWT France SAS Division water more 103 rue Charles Mi...

Reviews: