background image

ERROR 

CODE

ERROR TYPE

CAUSE

RESET AND RECOVERY

0

Cam Sensor Error The valve 

drive took 

longer than 

6 minutes 

to advance 

to the next 

regeneration 

position.

Unplug the unit and examine the powerhead.  

Verify that all cam switches are connected to the circuit board 

and funtioning properly. 

Verify that the motor and drive train components are in good 

condition and assembled properly.  

Check the valve and verify that the piston travels freely.  

Replace/reassemble the various components as necessary. 

Plug the unit back in and observe its behavior.  

The unit should cycle to the next valve position and stop.  

If the error re-occurs, unplug the unit and contact technical 

support. 

1

Cycle Step Error

The control 

experienced 

an unexpected 

cycle input

Unplug the unit and examine the powerhead.

Verify that all cam switches are connected to the circuit board 

and functioning properly. 

Enter Master Programming mode and verify that the valve type 

and system type are set correctly with regard to the unit itself. 

   

Step the unit through a manual regeneration and verify that it 

functions correctly.
If the error re-occurs unplug the unit and contact technical 

support.

2

Regen Failure

The system 

has not re-

generated for 

more than 99 

days(or 7 days 

if the control 

type has been 

set to Day-of 

Week)

Perform a Manual Regeneration to reset the error code. 
If the system is metered, verify that it is measuring flow by 

running service water and watching for the flow indicator on the 

display. 
If the unit does not measure flow, verify that the meter cable is 

connected properly and that the meter is functioning properly.
Enter a Master Programming Mode and verify that the unit is 

configured properly. 
As appropriate for the valve configuration, check that the correct 

system capacity has been selected, that the day override is set 

properly, and that meter is identified correctly. 
If the unit is configured as a Day-of- Week system, verify that at 

least one day is set ON. 
Correct the settings as necessary. 

  

 

3

Memory Error

Control board 

memory 

failure

Perform a Master Reset and reconfigure the system via Master 

Programming Mode. 
After reconfiguring the system, step the valve through a manual 

regeneration.
If the error re-occurs unplug the unit and contact technical 

support. 

UD

Upper Drive 

Synch

Power 

failure install 

programming

change

Valve will automatically recover

TROUBLESHOOTING 

ERROR CODES

NOTE: 

Error codes appear in the Service Display

                                                                                                                                                   

11

Summary of Contents for PROFESSIONAL II Series

Page 1: ...OPERATIONS MANUAL RESIDENTIAL FILTRATION SYSTEMS WITH FLECK 2510 AIO CONTROL VALVE PROFESSIONAL II SERIES MODEL NO ______________________ SERIAL NO ______________________ The Blake Group B W S TM...

Page 2: ...STARTUP WATER TEST RESULTS IRON________________________PPM WATER TEST RESULTS MANGANESE_________________PPM WATER TEST RESULTS HYDROGEN SULFIDE___________PPM WATER TEST RESULTS FEEDWATER pH__________...

Page 3: ...design Do not use where water is microbiologically unsafe Installation Requirements WATER PRESSURE A minimum of 30 psi of water pressure 2 7bar is required for regeneration valve to operate effectivel...

Page 4: ...er tank from venting backwards up the feed water plumbing 5 If not factory installed assemble the deflector to the distributor tube Deflector Installation Put a thin layer of silicone lube around insi...

Page 5: ...A M every third day This ensures the right times for each step of the regeneration process Under normal circumstances these settings will not need to be altered and should not be changed The frequenc...

Page 6: ...e this occurs a regeneration cycle will be initiated at the Set Regeneration Time Water flow through the valve is indicated by the Flow Indicator that will flash in direct relationship to flow rate Ti...

Page 7: ...event of power failure the control shifts into a power saving mode The control stops monitoring water usage and the display and motor shut down but it continues to keep track of the time and day for a...

Page 8: ...le button again The service icon will stop flashing Regenerating Immediately Press and hold the Extra Cycle button for five seconds 1 The timer advances to Regeneration Cycle Step 1 backwash and begin...

Page 9: ...eration time may be changed to accommodate households with varying schedules however once set to meet water quality requirements the cycle duration times should not be changed 1 Backwash 14 minutes Du...

Page 10: ...gle Tank DO Day Override 3 Days between Regenerations RT Regeneration Time 12 00 AM Regeneration Time BW Backwash 14 Minutes for Backwash Cycle BD Air Draw 40 Minutes for Air Draw Cycle RR Rapid Rinse...

Page 11: ...iser tube to ensure that no filtration media or gravel falls down into the riser tube The riser tube should be firmly seated and centered in the tank and should be flush with the top of the tank openi...

Page 12: ...backwash The backwash cycle should continue unit the water runs clear The valve can ow be cycled to service and the bypass valve opened allowing treated water to enter the household piping Caution mos...

Page 13: ...the unit and contact technical support 2 Regen Failure The system has not re generated for more than 99 days or 7 days if the control type has been set to Day of Week Perform a Manual Regeneration to...

Page 14: ...2 8 216 259 2 324 432 Media Wgt cf Service Rate GPM perSq Ft Backwash Rate GPM per Sq Ft Bed Depth Inches Percent Bed Expansion 50lbs 5 12 to 18 24 to 36 20 to 40 35 to 40LBS 3 5 to 5 10 to 12 30 to 3...

Page 15: ...NOTES...

Page 16: ...DISTRIBUTED BY AIO MANUAL Rev APR 2018 Blake Water Solutions 4 New Park Road East Windsor CT 06088 Tel 860 243 1491 The Blake Group B W S TM P N XO2510AIO...

Reviews: