GasAlertMicro Charger II
English Instruction Sheet
D5755/3 Page
4
Trimmed and folded dimensions: 4.125 (W) x 5.875 (H)
Figure 6. Inserting the Detector into the Charger
5.
Close the charger lid and press until the release tabs click.
The charger emits a confirmation beep and the LED lights red to
indicate charging is in progress.
6.
Allow the battery to charge fully (approximately 3.5-8 hours
depending upon the number of detectors being charged).
The LED changes to green when charging is complete.
When the detector is removed from the charger, the LED
deactivates.
Troubleshooting
If a problem occurs, refer to the following solutions. If the problem persists,
contact
BW Technologies by Honeywell
.
Table 6. Troubleshooting Guide
Problem
Possible
Cause
Solution
The detector is not
inserted correctly.
Firmly insert the detector in
the detector bay.
The charger
status LED does
not light when
the detector is
inserted.
Damaged or defective
battery pack.
Contact
BW Technologies
by Honeywell
.
There is no
audible beep.
Internal damage to
battery or charger.
Contact
BW Technologies
by Honeywell
.
The battery is above
or below the operating
temperature.
Leave the detector in the
charger. When the battery
reaches room temperature,
charging will begin (approx.
1 hour).
Severely depleted
battery.
Contact
BW Technologies
by Honeywell
.
There is an
audible beep,
but battery does
not charge.
Damaged or defective
battery pack.
Contact
BW Technologies
by Honeywell
.
Maintenance
a
Warning
No user-serviceable parts inside.
To maintain the charger in good operating condition, perform the following
basic maintenance as required.
•
Clean the exterior with a soft, damp cloth. Do not use solvents, soaps,
or polishes.
•
Do not immerse the charger in liquids.
Battery Pack Storage
When stored for extended periods of time, ensure the battery is fully
charged and then recharged every 30 days.
Replacement Parts and Accessories
a
Warning
To avoid personal injury or damage to the charger, use only
the specified replacement parts.
Table 7. Replacement Parts and Accessories
Model No.
Description
Qty
WMA-DOCK
Wall mounting kit
Kit of 2
GAMIC-BAT-03
Rechargeable battery pack
1
D5755/3
Instruction sheet
1
DOCK-CPLATE-K
Bottom cover plate kit
1
GAMIC-V-CHRG3
*
Vehicle charger adapter
1
*
Add suffix (-UK) for United Kingdom mains plug, (-EU) for European mains
plug, (-CH) for Switzerland mains plug, (-AU) for Australian mains plug.
Specifications
Size:
87.00 x 83.97 x 80.80 mm (3.4 x 3.3 x 3.2 in.)
Weight:
425.4 g (15 oz.)
Operating temperature:
10°C to 35°C (50°F to 95°F)
Humidity:
0 to 50%
Altitude:
2000 m (6561.66 ft.)
Power:
6 Vdc
, 1.0 A
Charger status LED:
Color-coded LED advises the following: charging,
charging complete, and charger fault
Charge time:
Typically 3.5 hours
Battery life:
Typically 300 charges
Pollution degree:
2
Installation category:
I
Certifications:
Approved to both U.S. and Canadian standards for CSA
International for use in ordinary locations.