E.D.M. Workbook Features and Functions
•
Open desired application.
•
Use the applications “
File/Open
“ menu options to
locate and open the data file.
If the recorded data file is compatible with the application, it
will open. If not the application will report an error in opening
the file.
Important
Some applications have an internal file size limits, and may
not load the entire file. Check the application’s specifications
prior to use.
Table A: Datalogger Status Codes
Codes Explanation
General Codes
— Normal
operation
G
Backlight is on
Sensor Codes
L Low
Alarm
H High
Alarm
T TWA
Alarm
U
Dual alarm (Low and TWA alarms)
V
Dual alarm (High and TWA alarms)
s STEL
alarm
u
Dual alarm (Low and STEL alarms)
v
Dual alarm (High and STEL alarms)
w
Dual alarm (TWA and STEL alarms)
x
Triple alarm (TWA, STEL and Low)
y
Triple alarm (TWA, STEL and High)
O
Sensor is over-ranged
C Calibrating
F Sensor
Failure
1
Alarm setpoint 1 (Low alarm)
2
Alarm setpoint 2 (High alarm)
3
Alarm setpoint 3 (TWA alarm)
4
Alarm setpoint 4 (STEL alarm)
D
Calibration due date (in days)
E
Last calibration (in days)
Z Auto-zeroing
Battery Status Codes
— Batteries
OK
B
Low battery alarm
K
Confidence beep is active