BÜTTNER ELEKTRONIK – Batt erie-Control-Booster MT BCB 30/30, MT BCB 40/40, MT BCB 60/40
14
Remark:
De-nude cable ends only:
- Signal cable 0.75 – 1.5 mm
2
: 9 mm
- Charging cables – 12 mm
Don’t use bootlace ferrules!
Option:
Cable length and cross-
sections see table 1
Cable length 50 cm each
and cross-sections**
NOTE:
Fusing protects cabling
against fire! Therefore allways
install close to battery.
Si.
5A
Si.
5A
Si.
I
Si.
II
To high load consumer (e.g. inverter for
air conditioning while driving) and 12 V
distribution
Adapt cross-section on biggest load
(e.g. inverter) as well
F I and F II > 100 A
Optionally use cherging cable set 2 – 6 m
with cable lugs and 250 A fusing.
See text.
BCB 30/30 6 mm
2
BCB 40/40 10 mm
2
BCB 60/40 16 mm
2
High-load relay
12 V 100 A (180 A)
Nr. MT 02156
Fix cable lugs
on relay
D+
+
-
negativ/ground
chassis
To be used for
mains detection signal,
for example CBE electrics
(conn. J10), if charger will
be de-activated
Temperature
Sensor
negativ/ground
chassis
negativ/ground
chassis
negativ/ground
chassis
negativ/ground
chassis
-Batt.
separate wiring acc.
table 1, if needed
Alternator
General all negative wirings
on negative-terminal of
BORD-Battery!
negativ/ground
chassis
G–
red
red
Installation type 4 – Special case: power consumption while driving more important
than charging capacity of the BCB
For operating conditions when sometimes higher currents are drawn than the BCB can supply will
need to flow to the board battery.