Instruction manual
SPEEDLINER 8050WS - SPEEDLINER 9080WS
Code M0205 - rev.1.0
(11/2010)
BUTLER S.p.A.
BUTLER Engineering & Marketing S.p.A. a s.u. -
Via Balduina 5/7 - 42010 Rio Saliceto (RE - Italy)
Page 29/51
Tel. +39 0522 647911, Fax +39 0522 649760
e-mail: [email protected] / www.butler.it
8.5.2 Thrust Run-Out with Automatic Acquisition
To carry out the thrust Run-Out with automatic acquisition procedure, press F3 to select
“thrust Run-Out” during the preliminary operations (see par. 8.4.2 on page 24)
.
The following screen will be displayed:
Figure 33
To carry out the thrust Run-Out operation, it is recommended to carefully follow the
displayed instructions.
RELEASE
detectors, so that they are free to oscillate upon wheel movement. Wait for
detectors to stop oscillating, and start moving vehicle backwards, very slowly, until vehicle
arrow matches the first target point.
Figure 34
As soon as vehicle matches target point, wait for detectors to stop oscillating. “STOP” will be
displayed for approx. three seconds, which are enough for the programme to acquire
measurement readings. Then the following screen will be displayed:
Vehicle
matches target
point
Vehicle thrust
direction (back)
Vehicle
starting point
Vehicle target
point